Programs (contd)
6 = Exit Mode
This program determines the way the panel functions during the exit time. There are four settings:
0 = Disabled
A disabled program is not available for use and cannot be selected at setting time. Program 1 cannot be
disabled.
1 = Timed
A timed program will become Set as the Exit timer expires.
2 = Final Door
A final door program will be set five seconds after a timed zone is closed if the rest of the zones are clear to
set.
NOTE: Final door programs must have a timed zone in order to operate correctly.
3 = Silent Timed
This operates exactly the same as Timed but completely silent without internal sounder signal.
NOTE: If a program is not selected when the user sets the system, program 1 will automatically set.
Therefore program 1 is usually considered as the Full Set Program containing all the zones.
LCD Keypad:
While in Engineer program mode, to set the Exit Mode ,
Press
to give a choice of programs or press
P>Programs is displayed then press
Select program 1, 2 or 3.
The first screen to appear is Program Edit Used Zones.
Press [6] to enter into Exit Mode edit. The Exit Mode can
now be changed.
Enter [0, 1, 2 or 3] for required Exit Mode.
NOTE: Program Mode DISABLED is not available in program 1.
Press
three times to save change and leave menu.
Accenta/Optima Engineer's Manual
until
.
40
P>Select Program
1 2 or 3
[Number]
P>Program Edit
Used Zones
[6]
P>Exit Mode
Mode
[0, 1, 2 or 3]
P>Program Edit
New Mode
P>Programs