Accenta/Optima Engineer's Manual

First Power Up

NOTE: For Optima Compact, fit the top cover on to the base and connect the speaker wires.
1
Check that the factory fitted links are connected to terminals PA, TAMP and T-A.
2
Fit the battery wires to the battery terminals (BATT).
3
On connecting the battery, the system will go into an alarm condition with an audible alarm indication.
After entry of a valid user code, there is a Tamper indication.
4
Fit the cover to hold down the tamper spring at the bottom centre of the board.
LCD INDICATIONS
Loop Tamper
5.
Enter the user code, press [0][1][2][3] factory set code. The alarm condition will cease and the system
will unset:
NOTE: The LCD keypad will show SYSTEM UNSET for 30 seconds first.
Sunday
02:36
6.
Immediately enter the engineer code by pressing [PROG][9][9][9][9]
7.
The system is now in Engineer program mode and can be programmed.
0>Walk Test
Panel
F1
1.6A
(red)
+
-
Black
12V battery
Figure 15. Battery Connection
01-Jan
Board
J4
+ -
AC
BATT
E
L
125mA Fuse
Transformer
LED INDICATIONS
15
First Power Up