Download Print this page

English - Johnson Pump SPX Bilge Mate Instruction Manual

Submersible bilge pump

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
> English
Bilge Mate - Submersible Bilge Pump, 12 V
Submersible bilge pump for pumping
bilge water in marine environment. To
be installed in the keelson.
Security
• The pump may not be used for other
liquids than water/bilge water.
• Always install the pump according
to the wiring diagram.
• Always use the fuse required, see
"Design features" below.
• The wire connections must be
sealed with a marine sealant.
• Insulation or cable sheathings must
be placed above the highest bilge
water level.
• Do not run dry.
Type designation
Part No: EU - 32-1015-01, US - 21405
Design features
EU
Max flow
30 l/min/
475 GPH
Amp Draw 2 A
Voltage
12 V DC
Fuse size
3 A
Hose size
3/4"
Height
100 mm
Weight
0.35 kg
Waste handling/
material recycling
At the products end of life, please
dispose of the product according to
applicable law. Where applicable,
please disassemble the product and
recycle the parts material.
4
US
30 l/min/
400 GPH
2,5 A
12 V DC
5 A
3/4"
100 mm
0.35 kg
Installation
1. Select the lowest point in your bilge.
Fasten the pump with
screws where convenient.
You may use a single
screw on an upright
member and simply
slide the screw into the
pump bracket slot.
2. Connect the brown wire to the posi-
tive (+) lead and switch and connect
the black wire to the negative (-)
lead. We suggest a 2 A fuse.
From pump
Battery
3. Make sure the pump oulet is level
or pointed slightly upward. The dis-
charge hose must have no loops or
sags which could cause an airlock.
Fasten the hose to the pump outlet
and to the thru hull connector, culling
off any excess hose that might sag.
For longer pump life, wire only as
directed and do not run dry. Turn the
switch off immediately after the bilge is
pumped.