i-SENS CareSens N POP Owner's Booklet
Hide thumbs Also See for CareSens N POP:

Advertisement

Quick Links

The Biosensor Expert
Owner's Booklet
i-SENS, Inc.
465-6 Wolgye4-dong, Nowon-gu
Seoul 139-845, Korea
www.i-sens.com
Medical Technology Promedt
Consulting GmbH, Altenhofstrasse 80,
D-66386 St. Ingbert, Germany
© 2012 i-SENS, Inc. All Rights Reserved PGA1E3171 REV1 10/2012

Advertisement

Table of Contents
loading

Summary of Contents for i-SENS CareSens N POP

  • Page 1 The Biosensor Expert Owner's Booklet i-SENS, Inc. 465-6 Wolgye4-dong, Nowon-gu Seoul 139-845, Korea www.i-sens.com Medical Technology Promedt Consulting GmbH, Altenhofstrasse 80, D-66386 St. Ingbert, Germany © 2012 i-SENS, Inc. All Rights Reserved PGA1E3171 REV1 10/2012...
  • Page 2 Welcome to the CareSens N POP Blood Glucose Monitoring System Thank you for choosing the CareSens N POP Blood Glucose Monitoring System. The system provides you with safe, fast, and convenient blood glucose in vitro (i.e., outside the body) diagnostic monitoring. You can obtain accurate results in...
  • Page 3: Table Of Contents

    Table of Contents Information Important Information:Read this First! Specifications CareSens N POP Blood Glucose Monitoring System Inserting or Replacing the Batteries CareSens N Blood Glucose Test Strip CareSens N POP Blood Glucose Meter CareSens N POP Blood Glucose Meter Display...
  • Page 4: Important Information:read This First

    Intended use: chemicals on the test strip to produce a small electrical CareSens N POP Blood Glucose Monitoring System is used for current. The CareSens N POP meter detects this electrical the quantitative measurement of the glucose level in capillary...
  • Page 5: Specifications

    5 seconds * Carrying Case * Batteries Sample type Fresh capillary whole blood Calibration Plasma-equivalent CareSens N POP BGM System may include the following items: * CareSens N Blood Glucose Test Strips Assay method Electrochemical * Lancets Battery life 1,000 tests...
  • Page 6: Inserting Or Replacing The Batteries

    Inserting or Replacing the Batteries CareSens N Blood Glucose Test Strip The CareSens N POP meter uses two 3.0 V lithium batteries. The CareSens N POP blood glucose monitoring system Before using the meter, check the battery compartment and measures blood glucose quickly and accurately. It automatically insert batteries if empty.
  • Page 7: Caresens N Pop Blood Glucose Meter

    CareSens N POP Blood Glucose Meter Warning! S Button capillary whole blood samples. Turns the meter on/off, confirms menu selections, and changes information Display Shows results, messages have been opened can be used up until the expiration date printed on the test strip box and vial label if the test strips are used and stored according to its storage and handling methods.
  • Page 8: Caresens N Pop Blood Glucose Meter Display

    CareSens N POP Blood Glucose Meter Display Setting up Your System Press and hold the button for 3 seconds to switch on the meter. After all settings are finished, press and hold the button for 3 seconds to turn off the meter.
  • Page 9 Setting the Time Format The meter can be set in the AM/PM (12-hour) or the 24-hour clock format. Press to select a format. The 24-hour format. After selecting the format press the button to enter the hour setting mode. 14 www.i-sens.com www.i-sens.com 15...
  • Page 10: Setting The Sound On/Off

    For example, in the case Note: Only when the sound is set to OFF, symbol appears when the expiration date is set to on the display. October of 2014, the meter displays "EP" at the start of November of 2014. 16 www.i-sens.com www.i-sens.com 17...
  • Page 11: Turn On The Hypoglycemia (Hypo) Indicator

    Before the HYPo indicator is set, ask your doctor or When you want to practice the test procedure using the diabetes nurse to help you decide what your hypoglycemia control solution instead of blood level will be. When using the meter for the first time 18 www.i-sens.com www.i-sens.com 19...
  • Page 12: Control Solution Testing

    The CareSens Control Solution can be purchased separately. applied within 2 minutes of the symbol appearing on the Please contact your authorized i-SENS sales representative. screen. If the meter turns off, remove the strip, reinsert, and start from step 1.
  • Page 13: Comparing The Control Solution Test Results

    CareSens N Test Strip and Meter may not be cause pain or skin calluses (thick hard skin). Choose a different working properly. Do no use your system and contact i-SENS site each time you test. sales representative.
  • Page 14: Preparing The Lancing Device

    The skin depth to retrieve samples will vary for Replace lancing device tip. various people at different sample sites. The lancing device's adjustable tip allows the best depth of skin penetration for an adequate sample size. The initial setting of three (3) is recommended. 24 www.i-sens.com www.i-sens.com 25...
  • Page 15: Preparing The Meter And Test Strip

    Press the release button. The CareSens N POP meter allows you to mark a result of a Remove the device from the finger. post-meal test with symbol. The post-meal test mark ( Wait a few seconds for a blood drop to can be attached just before applying the blood sample.
  • Page 16: Discarding Used Lancets

    3 seconds. Discard used test strips safely in appropriate containers. Caution: The lancet is for single use only. Never share or reuse a lancet. Always dispose of lancets properly. 28 www.i-sens.com www.i-sens.com 29...
  • Page 17: Alternative Site Testing

    Then press the release button while continuing to apply until sufficient (at least 0.5 μL, actual size: ) blood is drawn. Carefully lift the lancing device away from your skin. 30 www.i-sens.com www.i-sens.com 31...
  • Page 18: Hi And Lo Messages

    Try puncturing again in a smoother area. Note: Please contact your authorized i-SENS sales representative, if such messages are displayed even if you do not have hyperglycemia or hypoglycemia.
  • Page 19: Target Blood Glucose Ranges

    Target Blood Glucose Ranges Transferring Test Results Test results stored in CareSens N POP Reminders Your target ranges meter can be transferred from the meter to a computer using PC care from your healthcare professional Time of day software and cable. The 'Pc' is displayed...
  • Page 20: Meter Memory

    Meter Memory The CareSens N POP meter can save up to 500 glucose test Step 3 Viewing Pre-meal Averages results with time and date. If the memory is full, the oldest test Repeatedly press the to view 1, 7, 14, 30 and 90 day result will be deleted and the latest test result will be stored.
  • Page 21: Viewing Test Results

    3 seconds. The button ‘PP2’ character and the ‘OFF’ character will appear on the screen. Then the screen will change automatically to the memory check button mode without the ‘alarm’ character being displayed. 'alarm' vanishes 38 www.i-sens.com www.i-sens.com 39...
  • Page 22: Setting The Strip Expiration Date Indicator

    The test strip expiration date indicator can be set in the Step 3 Setting the Month CareSens N POP meter. The strip expiration date is printed on A number indicating the month will the test strip vial. blink in the left corner of the screen.
  • Page 23: Caring For Your System

    > Repeat the test after inserting a new test strip. as cell phones and microwave ovens. The CareSens N POP meter should be used only with This error message may appear when the CareSens N strips. wrong blood glucose test strip is used...
  • Page 24: General Troubleshooting

    If the error messages persist, contact your authorized i-SENS sales representative. test strip. The test result doesn't match the way you feel. test strip. Note: If the problem is not resolved, please contact your authorized i-SENS sales representative. 44 www.i-sens.com www.i-sens.com 45...
  • Page 25: Performance Characteristics

    The performance of CareSens N POP Blood Glucose Monitoring using CareSens N POP BGM Systems. System has been evaluated in laboratory and in clinical tests. Accuracy: The accuracy of the CareSens N POP BGM System Within Run Precision (Model GM505WAA, GM505WBA) was assessed by comparing *Blood avg.
  • Page 26: Warranty Information

    Warranty Information Manufacturer’s Warranty i-SENS, Inc. warrants that the CareSens N POP Meter shall be free of defects in material and workmanship in normal use for a period of five (5) years. The meter must have been subjected to normal use. The warranty does not cover improper handling, tampering, use, or service of the meter.

Table of Contents