MODEL: MDDF-16DEN7-QA3
REFRIGERANT: R290/0.075kg
MODEL: MDDF-20DEN7-QA3
REFRIGERANT: R290/0.075kg
The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for details.
Any updates to the manual will be uploaded to the service website, please check
for the latest version.
GD MIDEA AIR-CONDITIONING EQUIPMENT CO.,LTD.
Lingang Road Beijiao Shunde Foshan Guangdong People s Republic of China 528311
,
Before operating this product, please read the instructions
carefully and save this manual for future use.

Advertisement

Table of Contents
loading

Summary of Contents for Midea MDDF-16DEN7-QA3

  • Page 1 Any updates to the manual will be uploaded to the service website, please check for the latest version. GD MIDEA AIR-CONDITIONING EQUIPMENT CO.,LTD. Lingang Road Beijiao Shunde Foshan Guangdong People s Republic of China 528311 Before operating this product, please read the instructions...
  • Page 2: Table Of Contents

    SOCIABLE REMARK CONTENTS SAFETY PRECAUTIONS When using this dehumidifier in the European countries, the following information Warning ............................2 must be followed: Caution ............................2 Electrical information ........................4 DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection WARNINGS (for using R290/R32 refrigerant only) ................5 of such waste separately for special treatment is necessary.
  • Page 3: Warning

    SAFETY PRECAUTIONS SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions CAUTION must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. Do not cover the intake or Care should be taken when The seriousness is classified by the following indications.
  • Page 4: Safety Precautions Warning

    SAFETY PRECAUTIONS SAFETY PRECAUTIONS Contact the authorised installer for installation of this unit. If the air conditioner is knocked over during use, turn off the unit and unplug it from the WARNINGS (for using R290/R32 refrigerant only) main power supply immediately. Visually inspect the unit to ensure there is no damage. Do not use means to accelerate the defrosting process or to clean, other than If you suspect the unit has been damaged, contact a technician or customer service for those recommended by the manufacturer.
  • Page 5 SAFETY PRECAUTIONS SAFETY PRECAUTIONS WARNINGS (for using R290/R32 refrigerant only) 7)Ventilated area 1.Transport of equipment containing flammable refrigerants Ensure that the area is in the open or that it is adequately ventilated before breaking into the See transport regulations system or conducting any hot work. A degree of ventilation shall continue during the period that 2.Marking of equipment using signs the work is carried out.
  • Page 6 SAFETY PRECAUTIONS SAFETY PRECAUTIONS preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall with the manufacturer's specifications. be flushed with OFN to render the unit safe. This process may need to be repeated several NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection times.
  • Page 7: Control Pads On The Dehumidifier

    SAFETY PRECAUTIONS CONTROL PADS ON THE DEHUMIDIFIER NOTE: The control panel of the unit you purchased may be slightly different according the equipment are removed from site promptly and all isolation valves on the equipment are to the models. Continuous closed off.
  • Page 8: Other Features

    CONTROL PADS ON THE DEHUMIDIFIER CONTROL PADS ON THE DEHUMIDIFIER Display ES- Temperature sensor error-- Unplug the unit and Dryer mode(optional) Wet clothes Shows the set % humidity level from 35% to 85% or plug it back in. If error repeats, call for service. The unit can make the MAX dehumidification function auto start/stop time (0~24) while setting, then shows P2- Bucket is full or bucket is not in right position-- Empty...
  • Page 9: Identification Of Parts

    IDENTIFICATION OF PARTS OPERATING THE UNIT Identification of parts Positioning the unit A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed Front storage area, such as a closet, unless there is adequate circulation of air in and out of the area. Control panel Do not use outdoors.
  • Page 10: Removing The Collected Water

    CARE AND MAINTENANCE OPERATING THE UNIT Removing the collected water Removing the collected water 2. Continuous draining There are two ways to remove collected water. Water can be automatically emptied into a 1. Use the bucket 1. Pull out the bucket a little. floor drain by attaching the unit with a water When the bucket is full, the Full indicator light hose(not included).
  • Page 11: Troubleshooting Tips

    CARE AND MAINTENANCE TROUBLESHOOTING TIPS 3. Clean the air filter Before calling for service, review the chart below first yourself. The air filter behind the front grille should be checked and cleaned at least every two weeks Problem What to check or more often if necessary.