Download Print this page

Makita LH1040 Technical Information page 5

Table top miter saw 260mm (10-1/4")
Hide thumbs Also See for LH1040:

Advertisement

R
epair
< 5 > Removing blade case section
1. Remove living knife. See Fig.3-1.
2. Remove lever 54, support plate and pipe 9-126. See Fig.3-1.
The pipe 9-126 removed in this step, is used as a jig for removing rod 16 which functions as a pivot for blade case.
3. Loosen lever 54 and press table support down to the surface of blade case. See Fig.3-2.
Living knife
Hex flange
head bolt M8x20
Rod 16
4. Remove two M5x16 pan head screws. Now guard with guard holder can be removed from blade case. See Fig.3-3.
5. Remove hex socket button head screw M6 (adhesive type), flat washer 7 and ring 7. Now the linkage of link plate with
arm complete has been disconnected. See Fig.3-4.
6. Remove stop ring E-5, flat washer 6 and ring 6. then, link plate can be removed from blade case. See Fig.3-5.
Blade case
Fig.3-1
Support plate
Pipe 9-126
Table support
Fig.3-3
Guard holder
Guard
Stop ring E-5
Flat washer 6
Ring 6
Lever 54
Arm complete
Link plate
Pan head
screw M5x16
Ring 7
Flat washer 7
Fig.3-5
P 5 / 20
Fig.3-2
Table support
Lever 54
Fig.3-4
Blade case
Hex socket button
head screw M6
Link plate

Advertisement

loading

This manual is also suitable for:

Lh1040f