< 3 > Removing table
1. Lift up table by loosening two 54 levers which are equipped under the table. See Fig.2-1.
2. Lift up the table to the highest level. See Fig.2-1.
3. Remove pan head screw M5x16 and remove cover complete from riving knife. See Fig.2-2.
4. Remove 8 M5x16 countersunk head screws. Then, table can be removed from blade case. See Fig.2-2.
And remove compression spring 27 from blade case. See Fig.2-2.
(In case of model LH1040 without fluorescent job light)
4A. While lifting up the table, remove light circuit from the table. Then, table can be removed from blade case.
And remove compression spring 27 from blade case. See Fig.2-2.
(In case of model LH1040F with fluorescent job light)
Pan head
screw M5x16
Riving knife
< 4 > Mounting table
1. Secure table with 8 M5x16 countersunk head screws. Refer to Fig.2-2.
2. While lifting up table to the highest level, mount compression spring 21 by inserting it from the side.
3. Take the left step with referring to the above Figs.
Table
Hex lock nut M5-8
Cover complete
Countersunk head
screw M5x16 (8 pcs.)
Fig.2-1
Lever 54
Fig.2-2
Compression
spring 21