Servo ///
Motion ///
7)
Set the servo parameters (20SSC-H v.1.04 and later)
7.1)
When FX Configurator-FP is used and the forced stop is NOT being used:
If a forced stop switch is not used with the MR-J3-B servos, the servo forced stop
setting must be disabled before the servo series is set with the Configurator-FP as
follows:
Double click on 'Servo parameters' in the 'File data list' panel on the left-hand
side to modify the servo parameters. Be sure to change settings for BOTH the X
& Y axes.
Set the following item from the 'Kind' column:
Servo parameters
· Basic setting parameters → Function selection A-1 → Servo forced stop
selection →
Write
pressing the 'Write to module' button or by using [Online → Write to
module (Ctrl+T).] Select only the servo parameters and put a check
mark in the 'Flash ROM write' box as shown below. Click the OK button
and proceed with selecting 'Yes' and then 'OK.'
Reboot the power to the SSCNET system.
Servo parameters
· Servo amplifier series → Servo amplifier series →
Mitsubishi Electric Europe B.V. /// FA-European Business Group /// Gothaer Strasse 8 /// D-40880 Ratingen /// Germany
Tel: (02102) 4860 /// Fax: (02102) 486112 /// Email:info@mitsubishi-automation.com /// Web: www.mitsubishi-automation.com
Servo ///
Motion ///
"1: Invalid (Do not use the forced stop signal.)"
the servo parameters to the 20SSC-H BFM and Flash ROM by
for X- and Y axes.
"1: MR-J3-B"
Servo ///
Motion ///
Only the Servo
parameters are
selected to be written.
Check 'Flash ROM
write' so that these
settings are active
every time the power is
turned ON.
Servo ///
Motion ///
for X- and Y-axes.
Servo

Advertisement