Removing And Installing The Ws-F6K-Ge48-Af Inline-Power Daughter Card - Cisco WS-F6K-VPWR-GE Installation Notes

Power over ethernet daughter cards
Hide thumbs Also See for WS-F6K-VPWR-GE:
Table of Contents

Advertisement

Removing and Installing the WS-F6K-GE48-AF Inline-Power Daughter Card

Removing and Installing the WS-F6K-GE48-AF Inline-Power
Daughter Card
The WS-F6K-GE48-AF inline-power daughter card can be installed only on the following Ethernet
modules:
The WS-F6K-GE48-AF inline-power daughter card supports both IEEE 802.3af and the Cisco
Note
prestandard.
Removing the WS-F6K-GE48-AF Inline-Power Daughter Card
To remove the WS-F6K-GE48-AF inline-power daughter card on the Ethernet module, perform these
steps:
Loosen and remove the 12 screws and the 3 nuts securing the inline-power daughter card to the Ethernet
Step 1
module. (See
Tip
Three screws that secure the daughter card to the module pass through openings in the daughter card heat
sinks. We recommend that you use a No. 1 Phillips screwdriver equipped with a magnetic tip to remove
the three screws.
Figure 14
Catalyst 6500 Series Power over Ethernet Daughter Cards Field-Upgrade Installation Note
24
WS-X6148-GE-TX
WS-X6548-GE-TX
Figure
14.)
Removing the Inline-Power Daughter Card Mounting Screws and Nuts
(WS-F6K-GE48-AF)
Screw
Nut
78-10826-08