Using the thumb and forefinger of each hand, grasp the two ejector levers and exert a slight pressure
c.
to the left, deflecting it approximately 0.040 inches (1 mm) creating a small gap between the
module's EMI gasket and the module adjacent to it. (See
Do not exert too much pressure on the ejector levers because they will bend and get damaged.
Caution
While pressing down on the ejector levers, simultaneously close the levers to fully seat the module
d.
in the backplane connector. The ejector levers are fully closed when they are flush with the module
faceplate. (See
Tighten the two captive installation screws on the module.
e.
Note
Verify that the module STATUS LED is lit. Periodically check the STATUS LED. If the STATUS
f.
LED changes from orange to green, the module has successfully completed the boot process and is
now online. If the STATUS LED remains orange or turns red, the module has not successfully
completed the boot process and may have encountered an error.
Figure 40
FAN
STATUS
78-10826-08
Figure
40.)
Make sure that the ejector levers are fully closed before tightening the captive installation
screws.
Closing the Ejector Levers in a Vertical Slot Chassis
All ejector levers flush
with module faceplate
Catalyst 6500 Series Power over Ethernet Daughter Cards Field-Upgrade Installation Note
Installing the Ethernet Switching Module
Figure
39.)