Removing The Steam Duct And Seal; Figure 040-5: Steam Generator Temperature Regulator And Temperature Limiter; Figure 040-6: Steam Duct Retaining Screws - Miele DG 408 Series Technical Information

Table of Contents

Advertisement

DG 408x Steam Ovens

Figure 040-5: Steam Generator Temperature Regulator and Temperature Limiter

4.4

Removing the Steam Duct and Seal

1. Open the door.
2. Remove the steam generator.
3. Remove the insert from the steam generator housing.
4. Remove the bottom cover from the housing by gently pulling the cover from
the assembly while using a screwdriver to release the locking tabs, as
shown in Figure 040-4.
5. Remove the two steam duct retaining screws (T10s). See Figure 040-6, Item 1.

Figure 040-6: Steam Duct Retaining Screws

6. Remove the steam duct and seal.
35
Technical Information
Note:
When re-installing the seal,
make sure that the notch is
positioned as shown in
Figure 040-6, Item 2.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dg 4082Dg 4080

Table of Contents