Timing Charts; Operation Modes - Omron H5CR series Manual

Multifunction digital timer
Hide thumbs Also See for H5CR series:
Table of Contents

Advertisement

H5CR
SPECIFICATIONS continued
Memory function
Materials
Mounting
Connections
Weight
Approvals
Operating ambient temperature
Humidity
Vibration Mechanical durability
Malfunction durability
Shock
Mechanical durability
Malfunction durability
Variation due to voltage change
Variation due to temperature change
Insulation resistance
Dielectric strength
Service life
Mechanical
(SPDT relay)
Electrical

Timing Charts

OPERATION MODES

The gate input is not included on "economy" models H5CR-L and H5CR-LS.
Output mode A: Signal ON delay 1 (Timer resets when power comes on.)
Power
Start signal
Gate
Reset
Control output
Set value
Timing
UP
0
diagram
Set value
DOWN
0
Output mode A1: Signal ON delay 2 (Timer resets when power comes on.)
Power
Start signal
Gate
Reset
Control output
Set value
Timing
UP
0
Set value
diagram
DOWN
0
Retains preset values for 10 years at 25° C (77° F)
Plastic case
Panel or surface; Y92F-30
Panel, Y92F-30 mounting bracket included
mounting bracket included
8-pin round socket
Screw terminals
105 g (3.7 oz.)
160 g (5.6 oz.)
UL/CSA/SEV
-10° to 55°C (14° to 131°F) with no icing
35% to 85% RH
10 to 55 Hz with 0.75 mm single amplitude in 3 directions
10 to 55 Hz with 0.5 mm single amplitude in 3 directions
30 G each in three directions
10 G each in three directions
Included in "Repeat accuracy" specification
Included in "Repeat accuracy" specification
100 MΩ min. at 500 VDC between current-carrying terminal and exposed non-current-
carrying metal parts, and between non-continuous contacts.
2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminal and exposed
non-current-carrying metal parts for 100 to 240 VAC type
1,000 VAC for both 24 VAC and 12 to 24 VDC types
10 million operations minimum
100,000 operations minimum at 5 A, 240 VAC, resistive load (p.f. = 1)
One-shot
One-shot outputs can be set to 0.1 s, 0.5 s, 1 s, 5 s, 10 s, and 20 s.
Sustained output
120 g (4.2 oz.)
Timing begins at the leading edge of
the start signal. The control output will
be energized when the present value
equals the preset time. The output will
be sustained until a reset signal is
applied, until power is interrupted, or
for a programmable one-shot time
period.
Timing begins at the leading edge of the
start signal. The control output will be
energized if the start signal is sustained
for an amount of time equal to the preset
time. The output will be sustained until
the start signal is interrupted, until a reset
signal is applied, until power is
interrupted, or for a programmable one-
shot time period.