Installation Instructions
READ THIS FIRST! Electrical Requirements
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner's
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong outlet.
Failure to follow these instructions can result
in death, fire, or electrical shock.
IMPORTANT: Before you begin the actual installation of your air
conditioner, check your local electrical codes and the information below.
Your air conditioner must be connected to a power source with the same
alternating current (A.C.) voltage and amperage as marked on the name
plate located on the chassis. Only A.C. can be used. Direct Current (D.C.)
cannot be used.
CIRCUIT PROTECTION – Use on single outlet circuit only. An overloaded
circuit will invariably cause malfunction or failure of an air conditioner;
therefore, it is necessary that the electrical protection is adequate. Due
to momentary high current demand when the air conditioner starts, use a
"TIME DELAY" fuse or a HACR type circuit breaker. Consult your dealer or
power company if in doubt.
Refer to the electrical name plate located on the air conditioner chassis
(see Page 2) to determine the correct fuse or circuit breaker amperage for
your model (see Table 1 on Page 5 for electrical receptacle types).
The power cord has a plug with a grounding prong and a matching
receptacle is required.
Recommended Tools
1. Power Drill
2.
5
/
" Drill Bit
32
3. Gloves
4. Carpenters Level
1
5.
/
" Wrench
5
16
6.
/
" Wrench
1
4
7. #2 Phillips Screw Driver
2
8. Putty Knife or (wood stir stick)
3
24
WARNING
MOVING PARTS HAZARDS
Do not operate unit out of sleeve or
with front grille removed.
Do not place hands in blower or fan
blade areas.
Failure to do so can result in serious injury.
CAUTION
Excessive Weight Hazard
Use two or more people when installing your
air conditioner.
Failure to do so can result in back or other
injury.
4
5
6
7
8
ITEMS NOT TO SCALE

Installation Instructions for WSE Sleeve

(WSE Sleeve Accessory Sold Separately)
WARNING
Falling Object Hazard
Not following Installation Instructions
for mounting your air conditioner can
result in property damage, injury, or
death.
Mounting Hardware
ITEM
DESCRIPTION
QTY.
NO
1
SCREW, #12A x 2"
7
Figure 48
SIDE VIEW
24" MINIMUM REQUIRED FROM
TOP OF UNIT TO CEILING
INSIDE
WALL
1" MINIMUM SPACING REQUIRED
ON ALL SIDES OF UNIT
/
" MINIMUM BEYOND
7
8
INSIDE WALL
1" MINIMUM
3
/
" FOR SUBBASE
1
2
5
1
/
" MAXIMUM FOR SUBBASE
2
Wall Preparation
STEP 1. The wall opening required for a WSE SLEEVE is 17 ¼" high by
27 ¼" wide.
STEP 2. LINTELS must be used in opening of brick veneer and masonry
walls to support the material above the WSE SLEEVE. The
following considerations should also be given:
A. Masonry walls to support the material above the WSE SLEEVE.
B. Adjustable SUBBASE (SB) or other unit support must be
provided for panel wall type construction and for walls less
than 8" thick.
LINTELS
OUTSIDE WALL
5" (127 mm)
5" (127 mm)
WSE SLEEVE
WALL MOUNT
SCREW LOCATIONS
DRAIN EXTENSION
9
/
" MINIMUM BEYOND
16
OUTSIDE WALL
FRR011