Console Warning Messages

NOTE
The action you are required to take for each warning messages is described in the last line
of text in each message. If the required action does not solve the problem, call your
nearest HP Service Center for assistance.
WARNING: Not enough error-free contiguous memory (GoodMem).
command in the INFORMATION menu and the PDT command in the SERVICE menu
for error information.
WARNING: Memory page deallocation has been disabled because the Page Deallocation
Table (PDT) is full. If the Boot command is disabled, a memory error was
detected after the table was full.
SERVICE menu for error information.
WARNING: Memory has been initialized, but not tested as a result of FASTBOOT
being enabled.
menu and reboot the system.
WARNING: Memory configuration is not optimiZed for performance. refer to the
System Installation or Memory Installation manuals for memory
configuration guidelines.
WARNING: Memory SIMMs are not installed in the proper sequence.
has been disabled to prevent thermal damage.
configuration label for the proper sequence.
WARNING: Memory has been reconfigured due to a physical change or because the
Page Deallocation Table (PDT) was cleared.
only.
No action is required.
WARNING: Memory banks deallocated due to a SIMM size mismatch or a SIMM failure.
Refer to the ME command in the INFORMATION menu for error information.
Chapter 3
To test memory, disable the FASTBOOT command in the MAIN
Power On and Verification
Installation Verification
Refer to the ME
Refer to the PDT command in the
Refer to the Memory
This is for information
The BOOT command
3- 5