Advertisement

Quick Links

NetSure
RDB Series
Installation and User Manual, Section 6041
(Revision K, April 28, 2017)
Specification Number: 547692, 547693, 547499, 547694, 547695, 547615,
547696, 547697, 547503, 547500, 547698, 547699, 547501

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 547692 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vertiv 547692

  • Page 1 ™ NetSure RDB Series Installation and User Manual, Section 6041 (Revision K, April 28, 2017) Specification Number: 547692, 547693, 547499, 547694, 547695, 547615, 547696, 547697, 547503, 547500, 547698, 547699, 547501...
  • Page 2 NetSure ™ RDB Series Installation and User Manual, Section 6041 This page is intentionally blank. Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 3: Table Of Contents

    Connecting Power to the Loads ..........................14 Removing Power from the Loads ........................... 14 Alarms .................................. 14 Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 4: Admonishments Used In This Document

    SAFETY! Informs the reader of general safety information, reminders, precautions, or policies not related to a particular source of hazard or to fire safety. (ISO, ANSI, OSHA) Safety Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 [ii]...
  • Page 5: Important Safety Instructions

    Make sure that the total input current of the connected troubleshooting. systems does not exceed the current rating specified on the rating plate of the Rack PDU. Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 [iii] 547696, 547697, 547503, 547500, 547698, 547699, 547501...
  • Page 6 NetSure ™ RDB Series Installation and User Manual, Section 6041 This page is intentionally blank. Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 [iv] 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 7: Installation

    Unpack the shipping container, inspect all items for damage and Mounting Bracket verify that the shipment is complete and undamaged. Report any damage to your local Vertiv Co. representative and the carrier. If using the Rack PDU Mounting Kit, install the Rack PDU mounting Installing the Rack PDU bracket to the left and/or right rear frame of the rack using the appropriate hardware that fits to the cabinet that will be used.
  • Page 8 Installation and User Manual, Section 6041 Figure 2. Mounting Rack PDUs using Optional Mounting Bracket Kit Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 9: Electrical Connections

    "Ground Lead Bracket") and left unterminated on the other end. See Figure Figure 4. DC Output Connections Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 10: Connecting External Circuit Breaker Alarms

    Negative 48Vdc is provided to a set of alarm terminals if any circuit breaker is in the OFF position. See Figure Figure 5. Alarm Connections Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 11: Specifications And Technical Data

    2940 Max Amps rated at end of battery discharge (42V). PDU power rating limited to 200A, 8.4kW each. Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 12: Dimensions

    NetSure™ RDB L6, P/Ns 547692, 547693, 547499 Figure 6. NetSure™ RDB L6, P/Ns 547692, 547693, 547499 Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 13 Installation and User Manual, Section 6041 NetSure™ RDB L15, P/Ns 547694, 547695, 547615 Figure 7. RDB L15, P/Ns 547694, 547695, 547615 Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 14 Installation and User Manual, Section 6041 NetSure™ RDB M6, P/Ns 547696, 547697, 547503 Figure 8. RDB M6, P/Ns 547696, 547697, 547503 Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 15 Installation and User Manual, Section 6041 NetSure™ RDB H2, P/N 547500 Figure 9. RDB H2, P/N 547500 Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 16 Installation and User Manual, Section 6041 NetSure™ RDB H3, P/Ns 547698, 547699, 547501 Figure 10. RDB H3, P/Ns 547698, 547699, 547501 Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 [10] 547696, 547697, 547503, 547500, 547698, 547699, 547501...
  • Page 17 19.867 22.847 29.277 32.718 35.617 38.012 40.909 44.357 50.780 53.761 58.971 68.842 70.595 71.937 72.782 Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 [11] 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 18: Input Quick Connect Kit

    Output Cable Assemblies P/N 547595, P/N 547613 and P/N 555654 Figure 12. P/N 547595, P/N 547613 and P/N 555654 Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 [12] 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 19: Replacement Circuit Breakers

    547503 141802 (35A) 547698 142951 (50A) 547699 142952 (60A) 547501 142953 (70A) 547500 142955 (80A) Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 [13] 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 20: Operation

    Negative 48Vdc is supplied to a set of terminals when any circuit breaker on the Rack PDU is in the OFF position. These terminals may be connected to customer external alarm circuits. Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041...
  • Page 21 Phone 1.800.800.5260 [1] Contact Account Management for custom configurations. [2] Contact Spare Parts for parts and accessories. Spec. No: 547692, 547693, 547499, 547694, 547695, 547615, Document Code: Section 6041 [15] 547696, 547697, 547503, 547500, 547698, 547699, 547501 Revision K, April 28, 2017...
  • Page 22 Corporation, and its receipt or possession does not convey any right to reproduce, disclose its contents, or to manufacture or sell anything that it may describe. Reproduction, disclosure, or use without specific authorization from Vertiv Group Corporation is strictly prohibited. Names of companies and products are trademarks or registered trademarks of the respective companies.

Table of Contents