Power Connection; Perimeter Wire Layout - Bosch Indego Installation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 13

Power connection

4
Feed the power supply cable
4.1
through the docking station cover
and into the docking station.
Do not clip the cover yet, you will do this in step 5.9.
Check that the status indicator on the docking
station is now continously illuminated!
Switch on the Indego.
4.2
The on/off switch is located at the back of the mower. Please note, if the mower is not turned on, it will not charge.
At this point, nothing will be shown on the display.
Slide the mower into the
4.3
docking station for charging.
Make sure the on/off switch is on ( I ) before placing the
Indego in the docking station.
Although your Indego is already partly charged, it is recommended
to fully charge it before using it for the first time.
34
OFF
ON

Perimeter wire layout

5
The perimeter wire needs to be set up around the lawn to define the areas you want
to cut. Pegs will keep the wire in place. Use a mallet to insert them in the lawn. This part
of the installation will most likely take you the greatest amount of time. So we will take
you through it step by step.
Alternatively, it is also possible to bury the perimeter wire, with a maximum depth
of 5 cm.
Obstacle / 
Needed
Why
Object Type
space
Your Indego needs 30 cm of space to
Walls / fences / 
30 cm
run alongside a wall / fence and to turn
bushes / slopes
whilst mowing.
Your Indego can easily run over surfaces
Levelled surface
5 cm
that are level with the lawn. This is not
valid for loose ground (e.g. gravel).
This is for safety reasons. If there is a
power cut your Indego might travel up
Ponds, deep steps
> 75 cm
to 50 cm beyond the perimeter wire.
You do not want your Indego ending up
in a pond if there is a power cut!
The minimum required distance
between objects is 135 cm. This is
needed to ensure that both objects
can be excluded with the wire and
Between objects
> 135 cm
still provide enough space for Indego
to navigate between them. (2 x 30 cm
distance to the objects + 75 cm
between the wires). A reduced
distance may cause interference.
GB
Example
30 cm
5 cm
> 75 cm
30 cm
30 cm
> 75 cm
35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents