Troubleshooting - Soleus Air KFR/KFS Series Installation And Operation Instructions Manual

Kfr/kfs series split type room air conditioner - single zone wall mount heat pump
Table of Contents

Advertisement

Troubleshooting

RUN light blinks
1 time
Abnormality of room temperature
sensor.
2 times
Abnormality of defrost sensor.
3 times
Abnormality of indoor fan motor.
4 times
Abnormality of outdoor unit.
Continuous
No defect-unit in defrost mode.
blink
Defect
- 30 -
What to check
Open circuit or short circuit of room
temperature sensor.
Incorrect connection of the sensor.
Open circuit or short circuit of defrost
sensor.
Incorrect connection of the sensor.
Indoor fan motor is defective.
Bad connection to motor.
Compressor is defective.
Refrigerant is low.
Capacitor is defective.