Warning - Soleus Air KFR/KFS Series Installation And Operation Instructions Manual

Kfr/kfs series split type room air conditioner - single zone wall mount heat pump
Table of Contents

Advertisement

!
USE COPPER WIRES ONLY FOR POWER SUPPLY.
WARNING:RISK OF ELECTRIC SHOCK CAN CAUSE INJURY OR DEATH.
!
DISCONNECT ALL ELECTRIC POWER SUPPLIES BEFORE SERVICING.
!
DURING CONNECTION OF THE REFRIGERATION TUBES, IF EXCESSIVE
TORQUE IS IMPOSED ON FLARE NUTS, SERVICE VALVE ON DISCHARGE
LINE MAY BE DAMAGED. WHEN TIGHTENING FLARE NUTS OR NARROW
PIPE, TORQUE SHOULD BE ADJUSTED BETWEEN 13.7~18.6N.M
(140~190GF.CM).
DO NOT PUT INDOOR UNIT IN LOCATIONS WHERE IT MAY GET WET.
!
ELECTRICAL INSTALLATION MUST BE IN ACCORDANCE WITH LOCAL AND
!
NATIONAL ELECTRICAL CODES.
THE INSTALLATION OF THESE UNITS REQUIRES QUALIFIED PERSONNEL.
!
!
CERTIFIED(APPROVED) POWER SUPPLY CONDUCTORS MUST BE USED.
!
AN INDEPENDENT BRANCH CIRCUIT BREAKER MUST BE USED.
!
MAXIMUM INTER CONNECTING WIRE LENGTH SHOULD NOT EXCEED
11.3M (37FT.)
!
REFRIGERATING PIPE LENGTH MUST BE LIMITED BETWEEN 4~10M
( 13FT~33FT.) IF THE LENGTH EXCEEDS 7.62M(25FT.), THE COOLING
(OR HEATING) CAPACITY MAY BECOME IMPAIRED.
!
DIFFERENCE IN HEIGHT BETWEEN INDOOR AND OUTDOOR UNIT SHOULD
NOT EXCEED 7M(26 FT.).

WARNING

!
- 28 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kfs-12gKfr-12gKfr-18gKfr-24gKfs-12gwKfs-12gwh

Table of Contents