  • Page 1 RM5501K/RM6501K/RM7501K/RM8601K RS232/LAN Protocol Installation Guide...
  • Page 2: Table Of Contents

    Table of Contents Introduction ........................... 3 Wire arrangement ................................. 3 RS232 pin assignment ..............................3 Communication setting ............................4 Command message reference ..........................4 Connections and communication settings ................4 RS232 serial port with a straight cable ........................4 RS232 via LAN ................................5 RS232 via HDBaseT ..............................
  • Page 3: Introduction

    Introduction This document describes the hardware interface spec and software protocols of RS232 interface communication between Commercial Display and PC or other control unit with RS232 protocol. This set protocol allow users to assign the ID in the command to control the specify ID monitor. The set protocol contains two sections command: Set-Function and Get-Function In this document, "PC"...
  • Page 4: Communication Setting

    Communication setting Baud rate select: 38400bps (fixed)/ Data bits: 8 bits (fixed) Parity: None (fixed)/ Stop Bits: 1(fixed) Command message reference PC sends to Monitor command packet followed by "CR". Every time PC sends control command to the Monitor, the Monitor shall response as follows: 1.
  • Page 5: Rs232 Via Lan

    RS232 via LAN RJ45 port on a display PC or laptop LAN cable Find the Wired LAN IP address of the connected display from the OSD menu and make sure the display and the computer are within the same network. IP Procotol Port: 4660 RS232 via HDBaseT HDBaseT compatible device...
  • Page 6: Set-Function Listing

    Set-function listing The PC can control the LCD Monitor for specific actions. The Set-Function command allows you to control the LCD monitor behavior in a remote sit through the RS232 port. The Set-Function packet format consists of 11 bytes. Set-function description Item Description Length...
  • Page 7 0x30 0x38 0x73 0x24 0x30 0x37 0x36 0x0D 0x32 Reply (Hex Format) Command Name Length type 0x30 0x34 0x2B 0x0D 0x31 Example 2: Set Brightness as 176 for TV-02 and this command is NOT valid. Send (Hex Format) Command Name Length Command Value1...
  • Page 8: Set-Function Table

    0x30 0x34 0x2B 0x0D 0x31 Example 4: Set Tint as 75 for TV-03 and this command is NOT valid. Send (Hex Format) Command Name Length Command Value1 Value2 Value3 type 0x30 0x38 0x73 0x27 0x30 0x37 0x35 0x0D 0x33 Reply (Hex Format) Command Name Length...
  • Page 9 002: HDMI2 002: HDMI2 021 : HDMI3 021 : HDMI3 022 : HDMI4 022 : HDMI4 101 : android 101 : android 102 : OPS 102 : OPS Aspect Ratio 000: Default 001: 16:9 002: 4:3 003: Auto 004 : Panorama Mode 005 : Just Scan 006 : 14:9 007 : PC Mode...
  • Page 10: Get-Function Listing

    Mute 002: turn (State change) 002: turn (State change) Remote control 010 : Remote Up 011 : Remote Down 012 : Remote Left 013 : Remote Right 014 : Remote OK 020 : Remote OSD Menu 021 : Remote Source 023 : Remote Back (Android Back key) 031 : Blank...
  • Page 11 Command Name Length Command Value1 Value2 Value3 type Byte count 1 Byte 2 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte 1 Byte Bytes order Reply: (Command Type="r" or "-") If the Command is valid, Command Type ="r" Command Name Length...
  • Page 12 0x30 0x38 0x72 0x62 0x30 0x36 0x37 0x0D 0x35 Example 3: Get Tint from TV-0007 and this command is valid. The Tint value is 32. Send (Hex Format) Command Name Length Command Value1 Value2 Value3 type 0x30 0x38 0x67 0X65 0x30 0x30 0x30...
  • Page 13 0x30 0x34 0x2D 0x0D 0x31 Example 5: Get backlight sensor from TV-0007 and this command is valid. The lux value is 1786 (ASCII code). Send (Hex Format) Command Name Length Command Value1 Value2 Value3 Value4 type 0x30 0x39 0x67 0X6F 0x30 0x30 0x30...
  • Page 14 The value is +075 degree (ASCII code). NOTE: Positive degree is "+"ASCII code and negative degree is "-"ASCII code. Send (Hex Format) Command Name Length Command Value1 Value2 Value3 Value4 type 0x30 0x39 0x67 0X71 0x30 0x30 0x30 0x30 0x0D 0x37 Reply (Hex Format) Command...
  • Page 15: Pc Get-Function Command To Lcd Monitor

    PC Get-function command to LCD Monitor Value Range (ASCII Bytes) Get Function Cmd Code RS232 Type (Hex) (1) Input value: Byte1 - Byte2 - Byte3…Byte15 Model Info Byte2~Byte11=0x00 Byte1=0x01: Get Customer Name Byte1=0x02: Get Customer Model Name Byte1=0x04: Get Scaler Firmware Version Byte1=0x06: Get Serial Number (2) Return value: Byte1 - Byte2 - Byte3…Byte15 The Byte1 value at the return value should be the same as the...
  • Page 16 Aspect Ratio 000: Default 001: 16:9 002: 4:3 003: Auto 004 : Panorama Mode 005 : Just Scan 006 : 14:9 007 : PC Mode Language 000: English 001: Français 002: Español 003: 繁中 004: 简中 005: Português 006: German 007: Dutch 008: Polish 009: Russia...
  • Page 17 Byte1=0x05: Secondary DNS Byte1=0x06: MAC Address (2) Byte2~9 are reserved, should be 0x00. Return value: Byte1 - Byte2 - Byte3…Byte9 The Byte1 at the return value should be the same as the value of Byte1 at Input value. Byte2~Byte15 should be hex value format (1) If Byte1=0x00(IP Setup Mode) at Input value, the return value should be Byte1=0x00...