ICP DAS USA I-7565-H1 User Manual page 30

High performance usb/can converter
Table of Contents

Advertisement

The following is the demo of symbolic name file.
[CAN1Sym]
SymNum=2
ID1=0x100
Name1=Engine Speed
ID2=0x101
Name2=Engine Temp.
[CAN2Sym]
SymNum=1
ID1=0x200
Name1=Motor Speed
[CAN1Sym] : For CAN1 Symbolic Name Setting
SymNum : Symbolic Name Total Number
ID1 : The First Set CANID Value (HEX)
Name1 : The First Set CANID Symbolic Name
After loading the above symbolic name file, in OverWirte
mode, choose the "Sym" option. When receiving the
CANMsg with CANID=0x100 in "CAN1 RecvMsg" table, it
will show the symbolic name in ID field to replace the
original 100 value like Figure 4-6-3 and Figure 4-6-4.
I-7565-H1/H2 High Performance USB/CAN Converter User's Manual (Ver 1.7, Aug/2011) ------------- 30
Message Receive Area". (Only supported in OverWrite
mode and need to install symbolic file first. Provided in
Utility_v1.10 or newer)
Figure 4-6-3: "Hex" type in OverWrite mode

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I-7565-h2

Table of Contents