Operation Parameter; For Serviceman - Ferroli OMNIA H Series Installation, Maintenance And User Manual

Reversible heat pump for split installation
Table of Contents

Advertisement

Operation Parameter

This menu is for installer or service engineer to see all the
operation parameters.
■ At home page, go to ''MENU'' > ''OPERATION PARAMETER''.
■ Press ''OK''. There are five pages for the operating parame-
ter as following. Use ''▼'', ''▲'' to scroll.
OPERATION PARAMETER
OPERATE MODE
COMPRESSOR CURRENT
COMPRESSOR FREQUNCY
COMP.RUN TIME1
COMP.RUN TIME2
COMP.RUN TIME3
SCROLL
OPERATION PARAMETER
COMP.RUN TIME4
EXPANSION VALUE
FAN SPEED
BACKUP HEATER1 CURRENT
BACKUP HEATER2 CURRENT
T1 LEAVING WATER TEMP.1
SCROLL
OPERATION PARAMETER
T1 WATER FLOW TEMP.
T2
PLATE F-OUT TEMP.
T2B PLATE F-IN TEMP.
T3 OUTDOOR EXCHANGE TEMP.
T4 OUTDOOR AIR TEMP.
T5 OUTDOOR AIR TEMP.
SCROLL
OPERATION PARAMETER
Ta Room temp
Th COMP.SUCTION TEMP.
Th COMP.SUCTION TEMP.
Tw-0 PLATE W-OUTLET TEMP.
Tw-I PLATE W-INLET TEMP.
P1 COMP. PRESSURE1
SCROLL
OPERATION PARAMETER
P2 COMP. PRESSURE2
POWER CONSUMPTION
SCROLL
CONTROL SYSTEM
COOL
12A
24Hz
54MIN
65MIN
10MIN
1/5
1000HOUR
240P
600 R/MIN
0 A
0 A
25°C
2/5
25°C
30°C
45°C
-7°C
-7°C
-7°C
3/5
25°C
25°C
25°C
25°C
25°C
200kPa
4/5
--kPa
OKWH
5/5
INFORMATION
if some parameter is not be activated (or available), the para-
meter will show "--" .

FOR SERVICEMAN

About For Serviceman
FOR SERVICEMAN is used for installater and service en-
gineer.
■ Setting the composition of equipment.
■ Setting the parameters.
Go to ''MENU'' > ''FOR SERVICEMAN''. Press ''OK''.
FOR SERVICEMAN
Please input the password:
ENTER
OK
■ The FOR SERVICEMAN is used for installer or service en-
gineer. It is NOT instended the home owener alters setting
with this menu.
■ It is for this reason password protection is requierd to pre-
vent unanthorised access to the service settings.
How To Exit For SERVICEMAN
If you have set all the parameter.
Press ''BACK'', the following page will be appear:
FOR SERVICEMAN
Do you want to exit the for
serviceman?
NO
CONFIRM
OK
INFORMAZIONE
When you exit from the menu FOR SERVICEMAN, the
unit will be turned off.
0
0 0
ADJUST
SCROLL
YES
SCROLL
63

Hide quick links:

Advertisement

Table of Contents
loading