When the cursor is on OPERATE PREHEATING FOR FLOOR, Use ◄ ► to scroll to
YES and press OK. The page will be displayed as follows:
During preheating for fl oor, all the buttons except OK are invalid. If you want to turn off
the preheating for fl oor, please press OK. The following page will be displayed:
Use ◄ ►to scroll the cursor to YES and press OK, the preheating for fl oor will turn off.
Before fl oor heating, if large a amount of water remains on the fl oor, the fl oor may be
warped or even rupture during fl oor heating operation, in order to protect the fl oor, fl oor
drying is necessary, during which the temperature of the fl oor should be increased
gradually.
If FLOOR DRYING UP is selected, after press OK ,the page will displayed as follows:
When the cursor is on WARM UP TIME (t_DRYUP), KEEP
TIME (t_HIGHPEAK), TEMP. DOWN TIME (t_DRYD), PEAK
TEMP. (T_DRYPEAK), START TIME or START DATA, Use
◄ ► and ▼ ▲ to scroll and adjust the parameter.
t_DRYUP is the day for warming up.
t_HIGHPEAK is the last day of high temperature.
t_DRYD is the day of dropping temperature
T_DRYPEAK is the target peak temperature of water fl ow
during fl oor drying up.
The target outlet water temperature during fl oor drying up
described
in the picture below:
When the cursor is on OPERATE FLOOR DRYING? Use ◄ ► to scroll to YES and
press OK. The page will be displayed as follows:
During fl oor drying, all the buttons except OK are invalid. When the heat pump mal-
functions, the fl oor drying mode will turn off when the backup heater and additional
heating source is unavailable. If you want to turn off fl oor drying up, please press OK.
The following page will be displayed:
Use ◄ ► to scroll the cursor to YES and press OK. Floor drying will turn off.

Auto restart

The AUTO RESTART function is used to select whether the unit reapplies the user interface settings at the time when power
returns after a power supply.
Go to MENU> FOR SERVICEMAN> AUTO RESTART
Use ▼, ▲, ◄, ► to scroll and use OK to select YES or NON to enable or disable
the auto restart function. If the auto restart function is enabled, when power returns
after a power supply failure, the AUTO RESTART function reapplies the user interface
settings at the time of the power supply failure. If this function is disabled, when power
returns after a power supply failure, the unit won't auto restart.
42
SETUP OF THE SYSTEM
T_DRYPEAK
12.2 PREHEATING FOR FLOOR
Preheat for floor is
running for 25 minutes.
Water flow temperature is 20 °C.
CONFIRM
OK
12.2 PREHEATING FOR FLOOR
Do you want to turn of the
preheating for floor function?
CONFIRM
OK
12.3 FLOOR DRYING UP
WARM UP TIME(t_DRYUP)
KEEP TIME(t HIGHPEAK)
PEAK TEMP. (T_DRYPEAK)
START TIME
START DATE
SCROLL
T1S
t_DRYUP
t_DRYPEAK
12.3 FLOOR DRYING UP
The unit will operate floor
drying on 09:00 16-12-2015.
CONFIRM
OK
13 AUTO RESTART
COOL/HEAT MODE
DHW MODE
NO
YES
SCROLL
8 days
5 days
45°C
15:00
01-05-2015
1/2
t
t_DRYD
YES
NO
YES
NO
SCROLL