Configuring Web Control
provider categorization. If a URL or website matches custom criteria, then the URL will not be further
sent for categorization by the provider criteria.
The provider performs the categorization of URLs into the appropriate category, so there is no need
to configure specific match criteria for predefined categories.
As above, you can create your own custom categories which will match any website URLs against
text strings in that category. This allows custom categories to be created to suit business needs.
You can create up to 50 match criteria in total, so a category can have a maximum of 50 match
criteria, or 50 categories can each have one match criterion, as long as the total number of the
match criteria does not exceed 50.
Step 4:
awplus(config-web-control)#exit
awplus(config)#zone private
awplus(config-zone)#network engineering
awplus(config-network)#ip subnet 192.168.1.0/24 interface eth1
Step 5:
awplus(config-network)#exit
awplus(config-zone)#exit
awplus(config)#web-control
awplus(config-web-control)#rule permit movie from private.engineering
awplus(config-web-control)#exit
awplus(config)#exit
URLs containing the match criteria associated with the custom category movie can now be
accessed from the engineering network. Access to other URLs that do not match the custom
category movie will be blocked by the default Web Control action.
Step 6:
awplus#show web-control
Output 5: Example output for basic web control configuration:
awplus#show web-control
Web Control protection is enabled
Web Control default action is deny
Web Control is licensed
Categorization provider is Digital Arts
Statistics:
Categorization hits: 0/0
Rule hits:
Cache hits:
Cache size:
C613-22104-00 REV B
Configure an entity the rule applies to.
Create a rule for the category.
Display information about the state of Web Control.
0/0
(0.0%)
0/0
(0.0%)
0
(0.0%)
Advanced Network Protection