Service Manual - First Edition
B-2

Inspect the Electrical Wiring

Maintaining electrical wiring in good condition is
essential to safe operation and good machine
performance. Failure to find and replace burnt,
chafed, corroded or pinched wires could result in
unsafe operating conditions and may cause
component damage.
Electrocution hazard. Contact
with hot or live circuits may
result in death or serious injury.
Remove all rings, watches and
other jewelry.
1 Inspect the following areas for burnt, chafed,
corroded and loose wires:
· Ground control panel
· Hydraulic power unit module tray
· Battery pack module tray
· Scissor arms
· Platform controls
2 Turn the key switch to ground control and pull
out the Emergency Stop button to the
position.
3 Raise the platform approximately 8 feet (2.4 m)
from the ground.
4 Rotate the safety arm away from the machine
and let it hang down.
5 Lower the platform onto the safety arm.
Crushing hazard. Keep hands
clear of the safety arm when
lowering the platform.
Part No. 39528
Section 4 - Scheduled Maintenance Procedures
6 Inspect the center chassis area and scissor
arms for burnt, chafed and pinched cables.
7 Inspect the following areas for burnt, chafed,
corroded, pinched and loose wires:
8 Raise the platform and return the safety arm to
the stowed position.
9 Lower the platform to the stowed position and
turn the machine off.
ON
Genie GS-1530 & Genie GS-1930
TABLE B PROCEDURES
·
ECM to platform controls
·
Power to platform wiring
4 - 9