Deep Vacuum

Sensor Type: Thermistor
Port Type: (1) 3/8" and (3) 1/4" standard NPT male flare fittings
Range and Units:
50 to 9999 microns of mercury (English),
6 to 1330 Pascals (Metric),
0.06 to 13.3 mBar (Metric),
50 to 9999 mTorr (Metric),
0.05 to 10 Torr (Metric, equivalent to mmHg)
Best Resolution:
1 micron of mercury (below 2000 microns),
1 Pascal (below 250 Pascals),
0.001 mBar (below 2.5 mBar),
1 mTorr (below 2000 mTorr),
0.001 Torr (below 2.5 Torr)
Accuracy @ 77°F (25°C):
±(5% of reading + 5 microns of mercury), 50 to 1000 microns
±(5% of reading + 1 Pascal), 7 to 133 Pascal
±(5% of reading + 0.01 mBar), 0.067 to 1.33 mBar
±(5% of reading + 5 mTorr), 50 to 1000 mTorr
±(5% of reading + 0.005 Torr), 0.067 to 1 Torr

Wireless Compatibility

Latest compatibility at www.fieldpiece.com
Job Link System Minimum Device Requirement:
BLE 4.0 devices running iOS 7.1 or Android
Wireless Measurement Source Assignments:
Suction line temperature: Fieldpiece model JL3PC (set to blue)
Liquid line temperature: Fieldpiece model JL3PC (set to red)
Supply air psychrometer: Fieldpiece model JL3RH (set to blue)
Return air psychrometer: Fieldpiece model JL3RH (set to red)
Refrigerant weight scale: Fieldpiece models SRS3, SRS3P
38
Kitkat 4.4
TM

Manifold Diagram

Low Pressure Sensor
Deep Vacuum Sensor
LOW
Valve
VAC
Valve
LOW
Port
VAC
Port

Compliance

EN 300 328
2ALHR005
IC: Industry Canada
22518-BT005
High Pressure Sensor
HIGH
Valve
REF
Valve
HIGH
Port
REF
Port