Menu; Data Logging - Fieldpiece SMAN SM480V Operator's Manual

Refrigerant manifold + micron gauge (4 port)
Table of Contents

Advertisement

Menu

Press MENU to enter the menu where most
settings are located Use arrows to scroll through
the menu and press ENTER to select one of the
below menu items
LogData: Enter data logging setup mode (page 23).
(StopLog): If data logging, stop the log (page 23).
AutoOff: Enter auto off timer setup mode (page 24).
CalTemp: Enter calibration mode for Type K jacks (page 25).
Wireless Sources: Enter wireless source setup mode (page 26).
TSH Sources: Enter target superheat source setup mode (page 27).
Units: Enter units setup mode (page 28).
Vac Alarms: Enter vacuum alarm setup mode (page 28).
Mute: If unmuted, mute the speaker.
(Unmute): If muted, unmute the speaker.
Backlight Timer: Enter backlight timer setup mode (page 29).
Adv Pressure Cal: Enter advanced calibration mode for pressure
sensors (page 30).
F Ware: Enter firmware view and update mode (page 32).
Restore Settings: Enter restore factory settings mode (page 33).
(Delete Log File): If a log file is saved to the internal flash drive,
enter delete log file mode (page 34).
Format Drive: Enter format drive mode (page 34).
22

Data Logging

Log measurements and resulting calculations,
such as Superheat, at chosen spans and intervals
Save up to 9 Jobs (logs) to the internal flash drive
MENU/LogData
1. Use ARROWS to scroll through Jobs.
The display will alternate between the % free space on the drive and
the % of space the chosen Job uses.
2. Press ENTER to select.
If a Job already exists in that slot, use ARROWS then ENTER to choose
whether or not you want to save over that Job.
3. Use ARROWS to set the Span (total time).
It's a good idea to use new batteries if setting up a long span. If
batteries run out during a Job, the log will automatically stop and
save, then the SMAN manifold will turn off.
4. Press ENTER to select.
5. Use ARROWS to set the Interval (time between measurements).
6. Press ENTER to select and begin logging data until the Span ends.
LOG will blink to indicate the log is still active.
• Press MENU to exit setup at any time.
• Press MENU and select StopLog to stop the Job and return to
standard operation. The Job will be saved.
• To save battery life, the screen will turn off after 3 hours of logging,
but will continue to log. Press any button to turn the screen on.
• Some buttons and features (including auto power off) are disabled
until the Job ends.
• Jobs are saved as .csv files.
• Connect to your computer via the micro USB port under the
removable rubber cover. View its internal flash drive just like any
other USB drive.
23