Units

Each measurement can have its own unit of
measure
MENU/Units
1. Use ARROWS to scroll through the list of measurements.
2. Press ENTER to select.
3. Use ARROWS to scroll through units of measure.
4. Press ENTER to select and return to the list of measurements.
• Press MENU to exit at any time. If a change was made before
pressing ENTER, choose whether or not you want to save the change.

Vacuum Alarms

Set high and low vacuum alarms so you know
when you've reached an appropriate vacuum
(Low) and time how long it takes to rise after
blocking the pump from the system (High)
MENU/Vac Alarms
1. Use ARROWS to toggle between high and low alarm.
2. Press ENTER to select.
3. Use ARROWS to adjust the alarm trigger.
4. Press ENTER to select and exit or go to next.
• Press MENU to exit at any time. If changes were made, choose
whether or not you want to save changes.
• The low alarm cannot go higher than the high alarm.
• The high alarm cannot go lower than the low alarm.
• Press ENTER (ALARM) while in deep vacuum to activate the next
alarm (None >> Low >> High >> None).
28

Backlight Timer

The backlight turns off automatically after a set
time of no button presses
MENU/Backlight Timer
1. Use ARROWS to scroll through times (default is 2 min).
2. Press ENTER to select and exit. If changes were made, choose
whether or not you want to save changes.
• Press MENU to exit at any time. If changes were made, choose
whether or not you want to save changes.