Fieldpiece Wireless Clamp Meter OPERATOR'S MANUAL Model SC660 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com...
Type K temperature ports on the SC660. Take more accurate VAC and AAC readings on The SC660 is the top of the line clamp meter with variable frequency drives with True RMS sensing wireless functionality for the HVACR professional.
Quick Start Specifications Display: 10000 count dual display 1. For electrical testing, connect test leads to black Backlight: 5 minute duration with auto-off. Blue color "COM" and red "+" jacks. Overrange: (OL) or (-OL) is displayed 2. Rotate the dial to your desired measurement. Measurement rate: 3.3 times per second, nominal 3.
Page 4
SC660 Press to log measurements in Job Link™. CAT III 600V Deactivate autoranging and move the TRUE RMS AUTO OFF The SC660 is loaded with the measurement Select TYPE K 30V MAX Range H/M/m decimal point as desired. parameters essential for HVACR professionals.
Display Icons Battery Life Monitor Auto Power Off Enabled High Voltage Warning (>30VAC/VDC) Manual Ranging Data Hold Maximum Minimum Inrush AAC Wireless Enabled (searching if flashing) Wireless Signal Strength Bars Temperature Inputs Delta T Fahrenheit Easy to Read Display Celsius Continuity Test Diode Test Easily see your measurements on the large dual...
Test Parameters Volts AC (VAC) True RMS (50-500Hz) Test power lines (120, 220, 480VAC), test 24VAC going to controls, and test for transformer failure. Ranges: 1000mV, 10V, 100V, 600V Resolution: 0.1mV Accuracy: ±(1.2% + 10) 1000mV, 10, 100V range ±(1.5% + 10) 600V range Minimum Input Voltage Range: >20 digits Crest factor: ≤...
Page 7
Select the ADC value in the top display. Range H/M/m SC660 right side of meter to activate. Ranges: 100A, 400A Resolution: 0.01A Jaw Opening: 1.2in (30 mm) 3 Clamp meter around the motor’s start wire. Turn motor on. The Accuracy: ±(2.5% + 15) 100A, ±(2.0% + 10) 400A starting amp draw will hold on the upper display.
Page 8
MicroAmps DC (µADC) Microamps for flame rectifier diode test on a heater control. Connect leads between flame sensor probe and control module and turn heating unit on to read µA measurement. When the flame is on, there should be a measurable µADC signal, typically under 10µADC.
Resistance (Ω) HOLD Used for “ohming out” a compressor. A 0.01Ω resolution is useful to test the resistance between the terminal poles because the values are typically very low. Ranges: 100Ω, 1000Ω, 10kΩ, 100kΩ, 1000kΩ, 10MΩ, 50MΩ Resolution: 0.01Ω INRUSH Accuracy: ±(1.0% + 15) 100Ω, ±(1.0% + 5) 1000Ω...
Dual Temperature (T1, T2, T1-T2) Temperature Calibration Plug any Type K thermocouple directly into the meter to measure For accuracies of ± 1°F, calibrate both temperature. Test for proper airflow across the evaporator coil by thermocouples to a known temperature. A glass measuring delta T with the dual temperature inputs.
Page 11
Switch to . Plug black test lead into the COM (L1) port and red test lead show and Step 1 must to the VΩ (L2 L3) port on the SC660. be repeated. Step 2 With the black lead still on “L1”, move the red test lead to the...
Page 12
Expandability must be >80.0±5VAC. If not, the phase rotation test can not be performed and “Err” will show on Your SC660 is compatible with Fieldpiece the top display. Accessory Heads. With Fieldpiece Accessory Heads, 2 After phase rotation test is complete, press SELECT you can measure any available parameter, and read button to begin a new phase rotation test.
Page 13
(European) Wireless Auto-Connection Wireless Compatibility When powered on, SC660 will search for the last connected single-link For Receiving Wireless Measurements: EH4W, ET2W, LT17AW, SC57, wireless partner. If found, SC660 will automatically reconnect. If not found, wireless will stop searching after 2 minutes and an audible beep SC660, SC460 For Sending Wireless Measurements: JL2 Job Link™...
Press for 1 second to clear Range H/M/m 600V Select Manual Ranging SC660 and exit. Press to log an SC660 measurement Select Range H/M/m Range H/M/m CAT III SC660 600V in Job Link mobile app. See Wireless Section for Job...
Safety Information Do not apply more than rated voltages between input and ground. Never ground yourself when taking electrical Isolate capacitors from system and discharge measurements. Do not touch exposed metal pipes, them safely before testing. outlets, fixtures, etc., which might be at ground Te m p e r a t u re s w i t c h p re ve n t s l e av i n g potential, while taking measurements.
Advisory Statement for one year from date of purchase from an authorized Fieldpiece dealer. Fieldpiece will replace or repair the defective unit, at its option, subject to This device complies with Part 15 of the FCC rules. Operation is subject verification of the defect.