Power Up and Software Configuration
The WLP unit is normally mounted on a high pole (or wall) where it is
inconvenient to configure. However minimal connectivity must be verified
so the unit can later be configured and monitored from the ground. In
order to verify connectivity when installing the device, root devices must
be installed and powered up first.
The connectivity of the root device can be verified by the Ethernet ACT
LED. The root device MESH LED should also be on, indicating the device is
ready to connect wirelessly. When powering up a non-root device, the
MESH LED should be lit to indicate the device is connected wirelessly. WLP
boot time is about 2.5 minutes. The MESH LED indicator will light up after
the boot is completed.
Post-installation Testing Procedure
The purpose of the post-installation testing procedure is to verify
connectivity between the WLP and the network.
It is recommended that you perform the following tests:
1. Ping the device.
2. Establish telnet access and ping the access controller or the network
from the WLP unit CLI.