Sony XCG-CG160 Technical Manual page 24

Digital video camera module
Hide thumbs Also See for XCG-CG160:
Table of Contents

Advertisement

Trigger width detection
The figure shows the trigger signal negative polarity (detecting Low level width).
Trigger signal
Exposure
Sensor output
PTP (IEEE1588)
When running the unit in GigE Vision 2.0 mode, the unit can expose by synchronizing with a PTP (IEEE1588) server.
This can work as a master or slave of PTP (Precision Time Protocol). Operate as a slave when you have a grand master
device. When a grand master device is not available, you can make a single camera as a master and synchronize between
cameras. You can set the current time on the camera which is treated as a master. If you don't set the time, the time the
power was turned on would be 1/1/1970 0:00.
To use IEEE1588, you have to launch the camera in GigE Vision Version2.0 mode.
Register
GevVersionForStartUp
Restart the camera after you complete the settings.
Register
GevIEEE1588
GevIEEE1588SlaveOnly
GevIEEE1588Priority1
GevIEEE1588Priority2
GevIEEE1588DomainNumber
GevIEEE1588LogAnnounceInterval
GevIEEE1588LogSyncInterval
GevIEEE1588LogMinDelayReqInterval
GevIEEE1588AnnounceReceiptTimeout x3
You don't have to set these parameters in normal conditions.
The device to become the master will be determined automatically by the best master clock algorism.
Register
GevIEEE1588Status
The camera is available for use when the status is either master or slave.
It takes around 10 sec. to start synchronizing from when the function is enabled.
Parameter
GigE_Version_1_2 GigE Vision Version1.2
GigE_Version_2_0 GigE Vision Version2.0
Parameter
False
IEEE1588 OFF
True
IEEE1588 ON
False
Becomes the master depending on the condition
True
Works always as slave
128
Priority 1
128
Priority 2
0
PTP domain designation
Interval1s
Sending announce interval
Interval1s
Sending Sync frame interval
Interval1s
Minimum delay request interval
Announce receiving timeout
Parameter
Master
Master
Slave
Slave
24
Setting
Setting
Conditions