Atto Xstreamcore™ Fc 7500; Cooling And Airflow; Power; Fibre Channel Ports - ATTO Technology ATTO XstreamCORE FC 7500 Installation And Operation Manual

16/32-gigabit quad fibre channel to 12-gigabit sas storage controllers
Table of Contents

Advertisement

The ATTO XstreamCORE™ FC 7500 is a high-performance storage controller which adds 16-Gigabit Fibre Channel
connectivity to 12-Gigabit SAS or SATA storage devices.
The XstreamCORE™ FC 7500 is available in an industry-
standard 1U form factor for easy integration into racks.
Dimensions
Width: 17.3 inches
Length: 9.9 inches
Height: 1.7 inches (1U)
Weight: approximately 10 pounds

Cooling and airflow

Operating temperature: 5-40 °C external
Humidity: 10-90% non-condensing
Air enters from the front and is exhausted out the
connector side. Ambient air near the inlets should
not exceed 40°C. The unit automatically stops
operation if the temperature goes beyond this
threshold.
Do not block the enclosure's vents. The
XstreamCORE™ does not allow data transfer if overheating
occurs.

Power

The 7500 features two hot swappable power
supplies and can be operated with only a single
power supply inserted. Each power supply has a
standard IEC320 power receptacle and cooling fan.
The power requirements of the ATTO
XstreamCORE™ FC 7500 plus the power draw of
other equipment in the rack must not overload the
supply circuit and or wiring of this rack.
Input voltage: 100-240; VAC 1A; 50/60Hz.

Fibre Channel ports

The dual independent 16Gb/s Fibre Channel ports
connect the XstreamCORE™ FC 7500 to Fibre Channel
hosts using optical SFP+ connectors and multimode
fiber optic cable. Make sure all cables are anchored
securely at both ends with the proper connectors.
ATTO XstreamCORE™ FC 7500

SAS/SATA ports

The four (x4) 12Gb/s SAS/SATA connectors connect
storage devices into the Storage Area Network (SAN)
using mini-SAS HD cable plug connectors.

Management ports

Management is provided using the dual
100/1000BASE-T Ethernet ports accessible from two
right angle RJ-45 connectors, or the RS-232 serial
header console port accessible from the serial RJ-45
connector.

LED indicators

LED indicators can be viewed from the connector
side and the front side of the XstreamCORE™ FC
7500.
LEDs on the connector side are:
Power Supplies: One LED for each supply. Blue
indicates on and ready, while blinking Red indicates
an unplugged or failed supply.
Ready/Alert: On one shared LED a lit green means
ready, yellow indicates an alert condition.
Ethernet port connectors: A green LED embedded in
each Ethernet port connector indicates Link/Activity,
where green solid indicates link, blinking indicates
activity and OFF means no link is present. A second
green LED embedded in each Ethernet port
connector indicates connection speed, where green
solid indicates either a 100MbE or 1000MbE
connection.
Fibre Channel port: A lit green LED indicates link,
and OFF means no link. FC Port LEDs are located next
to the SFP connectors.
SAS/SATA device: SAS LEDs are located below the
mini-SAS HD connector. A lit green LED indicates a
link has been established on at least one PHY, and
OFF means there are no links.
LEDs on the faceplate are:
8 |
P a g e

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Atto xstreamcore fc 7550Atto xstreamcore fc 7600

Table of Contents