TROUBLESHOOTING
Problem
Blank display
Flow rate steadily reads
zero when there is flow
Display reads [ - ]
Flow rate intermittently
drops when there is flow
Jumpy reading
Probable Cause
Dead battery
Flow is below cutoff (very low)
There is air in the meter
Meter is installed backward
There is air in the meter
Improperly equalized
Pulsing flow
Rapidly changing conductivity
(chemigation applications)
Seametrics • 19026 72nd Avenue South • Kent, Washington 98032 • USA
(P) 253.872.0284 • (F) 253.872.0285 • 1.800.975.8153 • seametrics.com
AG2000 INSTRUCTIONS
Try...
Replace battery pack
Reading will resume when flow increases
Reposition meter for full pipe
Note flow direction arrow, reverse meter
Reposition meter for full pipe or rotate to avoid
bubbles
Check for proper equalization
Use external power source
(allows more flow averaging)
Install chemigation line downstream of meter
(or enough upstream for thorough mixing of
fluids before meter)