4. Lamp:
Installation and
replacement
2 screws
ProSpot utilises a Philips MSD 200W or 250W MH or equivalent.
The lamp is available from your authorised tas sales agent:
tas cod.
wattage
luminous flux
colour temperature
base
approximate life
tas cod.
wattage
luminous flux
colour temperature
base
approximate life
Disconnect mains prior to opening up the unit
The fixture's internal temperature can reach 150° C after 5 minutes, with a maxi-
mum peak of 350° C; ensure that the lamp is cold prior to attempting removal. The
fixture should be allowed to stand and cool for 10 minutes prior to its removal.
MSD lamps are part of the mercury vapour family of discharge lamps and must be
handled with great care. The lamp operates at high pressure, and the slight risk of
explosion of the lamp exists if operated over its recommended life.
We recommend, therefore, that the lamp be replaced within the manufacturer's spe-
cified lamp life.
mounting the lamp
1) Using a Philips head screwdriver remove the 4 which affix the top cover, located
as shown in the following diagram.
top cover
bottom cover
2) Remove the lampcover by removing the three thumbscrews as shown in the diagram.
Lamp cover
3 fastening screws
LM 5210
200 w
13500 lm
6600° K
GY 9,5
3000 hours
LM 5214
250 w
17000 lm
6600° K
GY 9,5
2000 hours
Attention