Error Messages - TAS ProSpot Manual

Table of Contents

Advertisement

20. Error messages

HEAt
This message will appear should you attempt to reignite the lamp prior to 5 minutes
passing since the unit was switched off. In this instance, the lamp may still be too hot
to reignite. This message will appear in the display if the lamp does not ignite within
28 seconds. When ProSpot has given this message, it will attempt to reignite the
lamp automatically.
LAEr
If lamp ignition does not occur within seven attempts (the HEAt message has been
displayed six times), the display will show LAEr, indicating that the lamp may be
damaged, failed, or absent.
This message is designed to protect the lamp ignition circuitry.
We recommend either installing or replacing the lamp. If the LAEr message continues
to appear in the display, check the external temperature, fan operation, air passages,
or contact your tas agent.
MbEr
This message indicates that the motherboard within the unit is not communicating pro-
perly with the control source.
CoEr (Color-wheel error)
This message may appear after a reset has been performed on the ProSpot if the
magnetic position indicator is not operating (either not operating or not reading pro-
perly) or the stepper motor is faulty (either defective or its cabling is not connected
properly).
The colour wheel will not have repositioned itself correctly after the reset.
rGEr (Rotating gobo-wheel error)
This message may appear after a reset has been performed on the ProSpot if the
magnetic position indicator is not operating (either not operating or not reading pro-
perly) or the stepper motor is faulty (either defective or its cabling is not connected
properly).
The gobo wheel will not have repositioned itself correctly after the reset.
IGEr (Rotating gobo indexing error)
This message may appear after a reset has been performed on the ProSpot if the
magnetic position indicator is not operating (either not operating or not reading pro-
perly) or the stepper motor is faulty (either defective or its cabling is not connected
properly).
The rotating gobo will not have repositioned itself correctly after the reset.
EFEr (Prism-wheel error)
This message may appear after a reset has been performed on the ProSpot if the
magnetic position indicator is not operating (either not operating or not reading pro-
perly) or the stepper motor is faulty (either defective or its cabling is not connected
properly).
The prism wheel will not have repositioned itself correctly after the reset.
FfEr
This error message indicates that the projector has overheated and that the lamp has
been automatically switched off by the protection circuitry. The message will remain on
the display until the temperature has fallen to an acceptable level. Subsequently, the
display will show HEAt, indicating that the lamp is too hot (see above).
Should this message appear, the projector should be either moved to a more suitable
position or, more simply, the air passages and fans should be checked.
SnEr
This message indicates that the lamp ignition sensor is not operating properly. This
message indicates the need for attention from your tas service agent.
PoEr
This error message indicates that the projector has momentarily been disconnected
from mains power.
FrEr
This error message indicates that the main voltage's frequency is other than the nor-
mal 50 or 60 Hz.