Shure MXA910 Manual page 66

Ceiling array microphone
Hide thumbs Also See for MXA910:
Table of Contents

Advertisement

MXA910 Response:
< REP METER_RATE sssss >
< SAMPLE aaa bbb ccc ddd eee fff ggg hhh iii jjj >
Stop Metering
Command String:
< SET METER_RATE 0 >
MXA910 Response:
< REP METER_RATE 00000 >
Get Post-Gate Metering Rate (firmware > v3.0)
Command String:
< GET METER_RATE_POSTGATE >
MXA910 Response:
< REP METER_RATE_POSTGATE sssss >
< SAMPLE aaa bbb ccc ddd eee fff ggg hhh >
Set Post-Gate Metering Rate (firmware > v3.0)
Where aaa, bbb, etc is the value of
the audio level received. Levels take
on values 000-060, which represent
actual audio levels of -60 to 0 dBFS
(value of 000 equals -60 dBFS).
aaa= output 1
bbb= output 2
ccc= output 3
ddd= output 4
eee= output 5
fff= output 6
ggg= output 7
hhh= output 8
iii= output 9
jjj= output 10 (echo reduction refer­
ence in channel)
A value of 00000 is also acceptable.
Where sssss is the metering rate in
milliseconds. Setting sssss= 0 turns
metering off.
Shure Incorporated
66/87

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents