Kalvis -100MG Installation And Service Manual page 9

Solid fuel water heating boiler with pellet burner
Table of Contents

Advertisement

Boiler model
Nominal power (Q
)
N
Minimum power (Q
)
min
Burner model
Control unit
Fuel type
Fuel moisture, no more than
Pellet fuel size, no more than
Fuel consumption at nominal power
Efficiency factor at Q
,
N
no less than
B class *
Heated area
C class *
Burning time without fuel refill (at Q
Boiler class acc. to LST EN 303-5
Service life time, no less than
Water capacity in the boiler
Water pressure in
no less than
the boiler
no more than
Maximum outflowing water temperature
Min. return water temperature during operation
Hydraulic resistance (Δt=20ºC/Δt=10ºC)
Working environment temperature
4
Draught from boiler *
Exhaust smoke temperature at nominal power, up
to
Operation voltage
Electrical power
Electrical protection class
flue pipe (relative diameter)
Connection branch
flue pipe branch pipe
pipe dimensions:
water discharge
heating system
height (H)
breadth (B)
Overall
dimensions, no
length (L)
more than:
breadth without el. panel (B1)
length without burner (L1)
Mass, no more than (10%)
1
*
Wood pellet quality shall be in line with DIN 51731, DIN plus standards.
2
*
Energy quantity calculated according to the requirements of STR 2.01.02:2016 Projecting and Certification of Energy Performance of
Buildings, expressed for Energy Performance of Buildings Classes B and C.
3
*
Using Ø8 wood pellets (7 % moisture and 17,5 MJ fuel heating value).
Fuel load combustion duration depends on fuel type, moisture, outside temperature, heat consumption.
4
*
Permanently constant draught from the boiler has to be ensured, so it is necessary to install smoke exhauster. For control of the smoke
exhauster, frequency converter and differential pressure sensor are recommended.
5
*
Dimensions are determined for a particular order at the time of
Peephole installed in the rear of the boiler is used to observe the combustion process visually.
For draught measurement in the boiler, branch pipes are installed on the both sides of the boiler, under
trimming covers, one branch pipe is used to pull a tube on, other end of the tube is led to the differential
pressure gauge installed in the control box (see fig. 6).
On the top of the rear wall of the boiler, smoke collector is installed, having three holes directed towards the
rear and the both sides. Flue pipe branch pipe is attached to one of the holes, selecting the direction, the
remaining two holes are covered with sooth removal lids.
In the boilers Kalvis-300MG ...-500MG, burner UNI-MAX 500 kW ... 300 kW is installed on rails
(see fig. 3).
More information about the burner and controller can be found in:
- „ECO-BURNER UNI-MAX 100-1000 kW Pellet Burner User Manual".
- „Burner control unit PLUM ecoMAX850P2-O (or KEY RK-2006LPGP2) for Pellet Boilers, Installation,
Service, Maintenance And Operation Manual".
KALVIS-100MG ... -500MG
LT
2019.03.18
kW
kW
%
mm
kg/hrs
%
2
2
m
2
3
) *
hrs
N
years
l
bar
(MPa)
ºC
ºC
mbar
ºC
Pa
ºC
V
W
mm
mm
mm (col)
mm (col)
mm
mm
mm
mm
mm
kg
- 9 -
Kalvis-250MG
Kalvis-300MG
250
300
75
90
UNI-MAX
UNI-MAX
250 kW
300 kW
PLUM ecoMAX850P2-O
wood pellets *
65
77
2925..8750
3510..10500
1400..4175
1680..5010
depending on fuel volume
1200
1400
0,127
0,136
585
1111
50 (2")
1900 *
5
2170
5
1440 *
1600
5
3320 *
4730
5
1140 *
1260
2990 *
5
3110
5
2500 *
2580
Table 1 continued
Kalvis-400MG
Kalvis-500MG
400
120
UNI-MAX
UNI-MAX
400 kW
KEY RK-2006LPGP2
1
10
 6 – 8
114
90
4680..14000
5850...17500
2240..6680
2800...8350
5
10
1400
2,5 (0,25)
4,0 (0,4)
90
50
0,185
3 - 30
4
180 *
130
230 AC
1411
IP 20
Ø 250
Ø 305
25 (1")
65 (2½")
2220
1760
4970
1420
3350
3000
500
150
500 kW
150
1600
0,254
1466
2220
1760
5270
1420
3650
3420