4.

Product description

4.1. Technical specifications

Boiler model
Nominal power (Q
)
N
Minimum power (Q
)
min
Burner model
Control unit
Fuel type
Fuel moisture, no more than
Pellet fuel size, no more than
Fuel consumption at nominal power
Efficiency factor at Q
,
N
no less than
B class *
Heated area
C class *
Burning time without fuel refill (at Q
Boiler class acc. to LST EN 303-5
Service life time, no less than
Water capacity in the boiler
no less than
Water pressure
in the boiler
no more than
Maximum outflowing water temperature
Min. return water temperature during operation
Hydraulic resistance (Δt=20ºC/Δt=10ºC)
Working environment temperature
4
Draught from boiler *
Exhaust smoke temperature at nominal power, up to
Operation voltage
Electrical power
Electrical protection class
flue pipe (relative diameter)
Connection
flue pipe branch pipe
branch pipe
water discharge
dimensions:
heating system
height (H)
Overall
breadth (B)
length (L)
dimensions, no
more than:
breadth without el. panel (B1)
length without burner (L1)
Mass, no more than (10%)
1
*
Wood pellet quality shall be in line with DIN 51731, DIN plus standards.
2
*
Energy quantity is calculated according to the requirements of STR 2.01.02:2016 Projecting and Certification of Energy Performance of
Buildings, expressed for Energy Performance of Buildings Classes B and C.
3
*
Using Ø8 wood pellets (7 % moisture and 17,5 MJ fuel heating value).
Fuel load combustion duration depends on fuel type, moisture, outside temperature, heat consumption.
4
*
Permanently constant draught from the boiler has to be ensured, so it is necessary to install smoke exhauster. For control of the smoke
exhauster, frequency converter and differential pressure sensor are recommended.
5
*
Dimensions are determined for a particular order at the time of

4.2. Design

Boiler body (see fig. 1, 2) is welded from steel sheets, it has cavities where water is heated. Body is
covered with thermal insulation coating and decorative panels.
Pellet burner is installed in the boiler hearth door. During combustion, hot combustion products, after
passing through hearth, go up and after passing through tubular heat exchanger escape from the boiler via
flue pipe.
Helicoidal turbulizers are inserted in the tubular heat exchanger to increase heat taking and improve
efficiency. Door of the heat exchanger has a gear turning the helicoidal turbulizers, which clean and push the
sooth accumulating on pipe walls inside the boiler.
In the bottom of boiler's hearth, there is the tray for falling ash with ash removal auger, which carries the
ash onto the ash removal conveyor, moving the ash into the ash box. Ash removal conveyor with the means of
chain is held in place in the special loop installed by the flue pipe, the loop can be installed on either side of
the boiler.
In the top part of the boiler, incoming and outflowing water branch pipes as well as boiler lifting lugs are
welded.
Digital controller is used to control and optimize boiler operation, monitor temperatures and control heating
system pumps. Emergency thermostat is installed in the controller. Sensor control unit is installed in the
control box which can be hung on the side of the boiler or on the wall of boiler house.
2
2
) *
3
N
bar (MPa)
- 8 -
Kalvis-100MG
Kalvis-130MG
kW
100
kW
30
UNI-MAX
UNI-MAX
100 kW
150 kW
%
mm
kg/hrs
20
%
1170..3500
1521..4550
2
m
560..1670
728..2171
hrs
years
l
990
ºC
ºC
mbar
0,014
ºC
Pa
ºC
V
W
455
mm
mm
mm (col)
mm (col)
5
mm
1900 *
1900 *
5
mm
1440 *
1440 *
5
mm
3120 *
3120 *
5
mm
1140 *
1140 *
5
mm
2790 *
2790 *
5
kg
1920 *
1920 *
Kalvis-150MG
130
150
40
45
UNI-MAX
150 kW
PLUM ecoMAX850P1-O
1
wood pellets*
10
 6 – 8
26
37
90
1755..5250
840..2505
depending on fuel volume
5
10
990
990
2,5 (0,25)
4,0 (0,4)
90
50
0,030
0,035
3 – 30
4
180 *
130
230 AC
585
585
IP 20
Ø 200
Ø 255
25 (1")
50 (2")
5
5
1900 *
5
5
1440 *
5
5
3120 *
5
5
1140 *
5
5
2790 *
5
5
1920 *
Table 1
Kalvis-200MG
200
60
UNI-MAX
200 kW
52
2340..7000
1120..3340
1200
0,070
585
5
1900 *
5
1440 *
5
3320 *
5
1140 *
5
2990 *
5
2500 *