24. If the Clean/Rinse Outlet Valve is installed, position it to discharge out toward the brine discharge connector.
25. One final time, fill the Rinse/Clean Solution Container with non-chlorinated product water.
26. Start the system. The rinse water rinses the entire system and discharge to waste.
27. Just prior to depleting the rinse water from the Rinse/Clean Solution Container, stop the system by pressing
the "START/STOP" button once to initiate the Automated Freshwater Flush Cycle every 7 days. Press the
"START/STOP" button twice to abort the Automated Freshwater Flush Cycle.
28. Reconfigure the system for normal operation:
a) Reconnect the Sea Strainer outlet line or reposition the Inlet Rinse/Clean Valve to normal operation position.
b) Remove the Product Relief Tube Kit.
c) Reconnect the High-Pressure Hose.
The system may now be operated or left unattended for up to 4 to 8 weeks, refer to the short-term storage
procedures. If the system will be stored without use for longer than 8 weeks, refer to the long-term storage
procedures to winterize the system. If the system will be stored in freezing temperatures refer to short-term storage
procedures or long-term storage procedures, as appropriate, to winterize the system.