Start/Stop button
1. Powers on and sets the system in its initial state.
2. When the system is producing water and the START/STOP button is pushed, the system stops all pumps and
diverts water into the sea.
3. Resets all faults.
Note that this button performs its designated action, regardless of whether or not you are browsing a menu.
Cycle button
This button allows the operator to cycle through the process and configuration parameters.
 Press the CYCLE button once to view to view the Display Menu.
 Press and hold CYCLE for 5 seconds to view the Configuration Menu.

Display Menu

This menu monitors measured values (e.g. pressure, flow and salinity); system states (e.g. FWF, running, FWP);
and timers. Press the CYCLE button once to view this menu and CYCLE again to scroll through the menu items.
Every time CYCLE is pressed, the next item is shown. If you release, and do not push the CYCLE button for more
than 5 seconds, you will return to the main screen.
1. Pre-Filter Press – Inlet pressure in Bar or PSI (pre-filter inlet)
2. HP Inlet Press – Inlet pressure in Bar or PSI (high pressure pump inlet)
3. Membrane Press – Membrane pressure in Bar or PSI