14. Perform a Feed pump motor rotational check. Ask an assistant to view the fan chapter of the Feed Water
Pump Motor while "jogging" this electric motor.
Press the "START/STOP" button; then immediately after the booster pump starts, press the "START/STOP"
button. Ensure that the Feed Water Pump Electric Motor is turning in the proper rotation.
To change rotation in DC systems, reverse polarity to the electric motor by interchanging the positive and
negative power leads to the motor. Then check the rotation again to ensure proper rotation.
Caution: The Feed pump is a very close tolerance vane pump. It requires water for lubrication. Operating
this pump dry will damage it within 30 seconds. Prime the system with water up to the Feed pump inlet
to ensure that it is wet prior to starting.
15. To start the system, press, the "START/STOP" button. If the system automatically shuts off immediately or after
20 seconds of operation, this may be due to a system fault. Look at the Controller to confirm whether a fault
has occurred. If Error ID 2 or 3 (High /Low Pressure Error) appears on the screen, ensure that the system feed
line is primed and that there is no air in the feed water line. Then, restart the system. Initial new system
commissioning may require priming of the feed water up to the Feed Pump inlet and through the pre-
filtration in order to build sufficient feed water pressure to maintain operation. Refer to the Troubleshooting
Section of this manual.
16. If there are no unforeseen abnormalities, the Ultra Whisper System pressure will automatically increase to
normal operating range immediately after starting. The R.O. BOOST will increase pressure to a point at which the
system produces the specified amount of product water. The next section (Production, Operating Pressure and
Operating Power Consumption) lists approximate expected pressures that a new system should develop when
operating in typical sea water of 35,000 PPM TDS at 77 F / 25 C. If any abnormality develops, stop the system
and correct the problem.
17. Although the system is producing "product water," the "product water" may not be "potable" for up to 30 minutes.
New RO Membrane Elements require operating time to flush storage chemical from the product water channel.
Daily operation requires operating time to flush dissolved solids from the product water channel. The operating
time required to flush the product water channel is normal for reverse osmosis systems. The salinity of the
product water diminishes gradually and is measured by the salinity probe. When the salinity of the product water
has diminished to the factory setting, the salinity controller will energize the 3-Way Product Water Diversion
Valve. At that instant, product water will be routed to the charcoal filter, pH neutralizer and UV sterilizer onward
to the potable water storage tank.
18.
Check for the following:
a) A constant feed water flow.
b) A consistent system pressure.
c) Leaks in the system.
d) Unusual noises or other occurrences.
19. Complete the "NEW SYSTEM INITIAL READINGS" form at the end of this chapter.
20. Prior to stopping the system, determine if the system will be stored for a period of time or if it will be turned over
to the owner and operated regularly. Failure to properly flush and/or store the system will lead to premature
fouling or drying out of the RO Membrane Element, which is not covered by the Sea Recovery Warranty and
is the liability of the person commissioning the system.
a) If the system will be operated within the next two weeks, no action is necessary. However, if the system will
be exposed to freezing temperatures, you must perform winterizing procedures. Freezing temperatures will
cause extensive damage if the system is not properly protected.
b) If the system will not be operated within the next two weeks, perform a freshwater flush. If the Sea Recovery
Automatic Freshwater Flush is installed, ensure that the potable water storage tank has potable water for
the freshwater flush to utilize in rinsing the system. If the system does not include an automatic freshwater
flush, then perform a manual freshwater flush.
c) If the system will not be operated within the next two months or longer, perform a long-term storage operation.
Caution: Do not use storage chemicals in the R.O. Boost. Doing so in a short term and/or long term storage
will damage the internal of the R.O. Boost. Please follow the storage closed loop configuration for storing
your system.
21. Stop the system by pressing the "START/STOP" button once. If the freshwater flush assembly is installed, the
freshwater flush lamp will illuminate, intermittently blinking for 2 minutes. This time delay is to allow the R.O.
BOOST to dissipate its pressure. After the 2-minute wait period, the freshwater flush automatic cycle will
begin, as indicated by a steady, non-blinking illumination of the freshwater flush lamp.