Kenwood TK-5210G Service Manual page 64

Vhf p25 transceiver
Table of Contents

Advertisement

TK-5210
Item
Panel tuning mode
6. Squelch
[Concentric SW]: A
Tight
1) Adj item: [W
[Wide]
Squelch (9)]
Adjust: [ *** ]
2) Adj item: [L] → [C]
→ [H]
SSG output: 12dB
SINAD level +6dB
(MOD: 1kHz/±3kHz)
[Narrow]
[Concentric SW]: B
1) Adj item: [N
Squelch (9)]
Adjust: [ *** ]
2) Adj item: [L] → [C]
→ [H]
SSG output: 12dB
SINAD level +6dB
(MOD: 1kHz/±1.5kHz)
7. RSSI
[Concentric SW]: A
(–120dBm)
1) Adj item: [W RSSI
[Wide]
(–120)]
Adjust: [ *** ]
2) Adj item: [L] → [C]
→ [H]
SSG output:
–120dBm (0.22µV)
(MOD: 1kHz/±3kHz)
[Narrow]
[Concentric SW]: B
1) Adj item: [N RSSI
(–120)]
Adjust: [ *** ]
2) Adj item: [L] → [C]
→ [H]
SSG output:
–120dBm (0.22µV)
(MOD: 1kHz/±1.5kHz)
[P25]
[Concentric SW]: C
1) Adj item: [A RSSI
(–120)]
Adjust: [ *** ]
2) Adj item: [L] → [C]
→ [H]
SSG output:
–120dBm (0.22µV)
(MOD: 1kHz/±1.5kHz)
64
(
G
)
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Squelch
SSG
Tight (Wide)]
AF VTVM
2) Adj item: [Frequen-
Oscilloscope
cy]
[Low] → [Center] →
[High]
SSG output: 12dB
SINAD level +6dB
(MOD: 1kHz/±3kHz)
1) Adj item: [Squelch
Tight (Narrow)]
2) Adj item: [Frequen-
cy]
[Low] → [Center] →
[High]
SSG output: 12dB
SINAD level +6dB
(MOD: 1kHz/±1.5kHz)
1) Adj item: [RSSI
SSG
(–120dBm) (Wide)]
AF VTVM
2) Adj item: [Frequen-
Oscilloscope
cy]
[Low] → [Center] →
[High]
SSG output:
–120dBm (0.22µV)
(MOD: 1kHz/±3kHz)
1) Adj item: [RSSI
(–120dBm) (Nar-
row)]
2) Adj item: [Frequen-
cy]
[Low] → [Center] →
[High]
SSG output:
–120dBm (0.22µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item: [RSSI
(–120dBm) (P25)]
2) Adj item: [Frequen-
cy]
[Low] → [Center] →
[High]
SSG output:
–120dBm (0.22µV)
(MOD: 1kHz/±1.5kHz)
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
Universal
connector
Panel
ANT
Panel
Universal
connector
Adjustment
Specifi cations /
Parts
Method
[Panel tuning mode]
After input signal
from SSG, press
[B] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
[Panel tuning mode]
After input signal
from SSG, press
[B] key to store the
adjustment value.
[PC test mode]
After input signal
from SSG, press
[Apply] button to
store the adjust-
ment value.
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents