Kenwood TK-5210G Service Manual page 57

Vhf p25 transceiver
Table of Contents

Advertisement

Item
Panel tuning mode
3. Balance *2 1) Adj item: [Balance]
Adjust: [ *** ]
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item: [L] → [LC]
→ [C] → [CH] → [H]
Adjust: [ *** ]
PTT: ON
Press [B] key to
store the adjust-
ment value.
4. Mic
1) Adj item: [Mic
Sensitivity
Sense]
Adjust: [ *** ]
PTT: ON
Press [B] key to
store the adjust-
ment value
5. Max
[Concentric SW]: B
Deviation
1) Adj item: [N FM
*2
Max Dev]
[Narrow]
Adjust: [ *** ]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item: [L] → [LC]
→ [C] → [CH] → [H]
PTT: ON
Adjust: [ *** ]
Press [B] key to
store the adjust-
ment value.
[Wide]
[Concentric SW]: A
1) Adj item: [W FM
Max Dev]
Adjust: [ *** ]
2) Adj item: [L] → [LC]
→ [C] → [CH] → [H]
Adjust: [ *** ]
PTT: ON
Press [B] key to
store the adjust-
ment value.
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item: [Balance]
Deviation
Deviation meter
meter
LPF: 3kHz
Oscilloscope
HPF: OFF
2) Adj item: [Frequen-
cy]
[Low] → [Low'] →
[Center] → [High']
→ [High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
1) Adj item: [Mic Sen-
Deviation
sitivity]
meter
PTT: Press [Trans-
Oscilloscope
mit] button. Press
AG
[OK] button to store
AF VTVM
the adjustment
value.
1) Adj item: [Max
Deviation
Deviation (Narrow)]
meter
Deviation meter
Oscilloscope
LPF: 15kHz
HPF: OFF
2) Adj item: [Frequen-
cy]
[Low] → [Low'] →
[Center] → [High']
→ [High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
1) Adj item: [Max
Deviation (Wide)]
2) Adj item: [Frequen-
cy]
[Low] → [Low'] →
[Center] → [High']
→ [High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
Panel
ANT
Panel
Panel
ANT
Panel
TK-5210
Adjustment
Specifi cations /
Parts
Method
[Panel
Make the demodu-
tuning
lation waves into
mode]
square waves.
[C],[D]
[PC
test
mode]
[ ],[ ]
[Panel
Write the value as
Mic sensitivity
tuning
followings.
check:
mode]
48 (Reference
15mV±3.5mV
[C],[D]
value)
[PC
Adjust AG input
test
to get a standard
mode]
MOD., 3.0kHz.
[ ],[ ]
[Panel
2.0kHz
±15Hz
tuning
(According to the
mode]
larger +, –)
[C],[D]
[PC
test
mode]
[ ],[ ]
4.0kHz
±50Hz
Set it the ad-
justment value
obtained from the
[Max Deviation
Adjust [Narrow]]
adjustment of step
2).
(
G
)
Remarks
57