Electrolux RO 400 User Manual
Electrolux RO 400 User Manual

Electrolux RO 400 User Manual

Direct flow
Hide thumbs Also See for RO 400:

Advertisement

I
N F
O
U S E R M A N U A L
WATER PURIFIER
RO 400 DIRECT FLOW
822 90 16-13

Advertisement

Table of Contents
loading

Summary of Contents for Electrolux RO 400

  • Page 1 U S E R M A N U A L WATER PURIFIER RO 400 DIRECT FLOW 822 90 16-13...
  • Page 2 RO 400 DIRECT FLOW THANK YOU for choosing the RO 400 water purifier. We are confident it will give you many years of trouble-free service. To achieve the best results when using your new water purifier, we recommend that you read this user manual carefully and keep it in a safe place for future reference.
  • Page 3: General View Of The Appliance

    GENERAL VIEW OF THE APPLIANCE Control panel Filter container Base plate Filter container Supplied with the RO 400: Bracket for reject water hose* Elbow for purified water hose* Hose for discharge of reject water to Filter spanner waste pipe Self-adhesive information panel...
  • Page 4: Your New Water Purifier

    Part no. 919 24 00-01 Take hold of the rear hand-grip and the front edge of Descaling/cleaning agent the RO 400 and carefully lift the appliance out. The for Water Purifiers Part no. 150 72 07-00 appliance can be damaged if it is lifted in any other way.
  • Page 5: Table Of Contents

    Preparing the RO 400 for storage ....18 CONTENTS Protecting the RO 400 against freezing during storage..........19 SAFETY INFORMATION REGULAR CARE OF THE RO 400 Concerning the use of the RO 400 ....7 Points to remember ........19 Concerning installation and service ....7 8-12 INSTALLATION 20-21 TECHNICAL DATA Where to install the RO 400 ......8...
  • Page 6: Safety Information

    SAFETY INFORMATION The RO 400 Direct Flow is a very safe appliance, but even so it is important that everyone using it should be thoroughly familiar with the way it works and its safety features. To prevent mishaps and problems you should read the " Safety Information " on these pages, and carefully follow the instructions in the "...
  • Page 7: Concerning The Use Of The Ro 400

    • Depending on the incoming water quality it could • It is important that the water purifier should be be a delay of up to 60 sec. before the RO 400 installed in the upright (standing) position. indicates that the optimum water purification level has been reached.
  • Page 8: Installation

    • When choosing the site, make sure there will be adequate ventilation all around the appliance. There must be a gap of 20 mm between the sides of the RO 400 and any adjacent fitments or walls. The connection points of the RO 400 allow you to route hoses and cables in any direction out from the appliance.
  • Page 9: Electrical And Plumbing Connections

    The RO 400 is connected to the cold water supply (temperature range 2 - 40 °C) via a polyethylene feed hose (3). The cold water pipe should have a valve easily accessible for shutting off the supply, see Fig.
  • Page 10: Connecting The Reject Water Hose

    INSTALLATION Connecting the reject water hose The reject water hose (for discharge of water to a house- hold waste pipe) can be extended up to 4 metres. The smallest internal diameter is 13 mm. The bracket (supplied) should be secured at a height of at least 50 mm and a maximum of 500 mm above the top of the appliance.
  • Page 11: Connecting Up The Appliance

    INSTALLATION Connecting up the appliance Before moving the RO 400 into its permanent place, connect the three hoses to the appliance as shown in Fig. C. Connect the purified water hose from the purified water tap to the appliance. Press this end of the hose all the way home, as far as the line marked on it (about 17 mm).
  • Page 12: The Flushing Procedure

    2 Connect the electrical plug to the wall socket again. The Levels I and II will now flash once and the current RO 400 will now switch automatically to flushing mode. water quality level will be displayed when the light for...
  • Page 13: Using The Ro 400

    Once the RO 400 has been installed and calibrated according to the " Installation " instructions, it is ready for use. The RO 400 has an electronic control system which makes it easy for you to use. Normally you will only need to remember a few points: •...
  • Page 14: Maintenance

    11 Close the front cover and reconnect the electrical plug. Flushing will take place automatically. This completes the procedure for replacing filter and the RO 400 is ready for use again. TO REPLACE FILTER Replace filter when the pattern of indicator lights on...
  • Page 15 MAINTENANCE...
  • Page 16: Descaling

    Stir until the powder has dissolved, see Fig. A. 5 Screw the container (containing the descaling solution) back onto the appliance with the aid of the filter spanner. 6 Turn on the tap for purified water and let the RO 400 operate for 45 seconds.
  • Page 17: Disinfection

    4 Screw the container (containing the solution) back onto the appliance with the aid of the filter spanner. 5 Turn on the tap for purified water and let the RO 400 operate for 45 seconds. 6 While the tap is still on (open), disconnect the electrical plug, see Fig.
  • Page 18: To Clean The Grid

    8 Connect the appliance to the electrical supply again. It will flush automatically. Preparing the RO 400 for storage If the RO 400 is not going to be used for a period longer than four months, it needs to be filled with a special product to keep it in good condition.
  • Page 19: Protecting The Ro 400 Against Freezing During Storage

    -30°C. 1 Follow steps 1–4 of the instructions: "Preparing the RO 400 for storage", but here, at step 2, you need to disconnect the appliance ends of the hoses for feed water and reject water. Bear in mind that they will contain water.
  • Page 20: Technical Data

    < 60 dB(A) Sound level when installed in under-sink cupboard Environmental specifications 2 - 43 °C air temperature 25 – 95 % relative humidity Requirements of feed water to the RO 400: Chemical requirements: <200 mS/m conductivity <1500 mg/l /salt <900 mg/l...
  • Page 21 TECHNICAL DATA Examples of rejection for substances which may be present in water INORGANIC SUBSTANCES >99 -turbidity >99 -colour Cations/Metals >96 -sodium >97 -potassium >99 -calcium (hardness) >99 -aluminium >99 -iron >99 -manganese Cations/Heavy metals >99 -copper >99 -lead >99 -zinc >99 -mercury...
  • Page 22: If The Ro 400 Stops Working

    IF THE RO 400 STOPS WORKING Trouble-shooting table To protect both the user and the appliance itself from incorrect use, the RO 400 has built-in warning (alarm) devices which cause it to stop working under certain conditions. The table below lists these warnings and their probable causes.
  • Page 23 • Adjust the adjusting screw on the tap see "To The tap is leaking, which causes the adjust the tap". RO 400 to respond constantly to the loss of pressure. The adjusting screw in the tap may need adjustment, or washers in the tap may be damaged.
  • Page 24: To Adjust The Tap

    5 Refit first the lever, then the main tap pipe. Check that the seals/washers on the main tap pipe are in good condition. 6 Reconnect the electrical plug and let the RO 400 flush automatically. 7 Test the appliance. If the problem persists, adjust the...
  • Page 25: Service And Spare Parts

    If you have tried everything relevant described in the table, and still cannot get your RO 400 to work, then it is time to call service. Service using genuine spare parts is available via your dealer.
  • Page 26 Electrolux Home Comfort Appliances • Product Division • Luxbacken 1 • S-105 45 Stockholm • Sweden • Tel +46-8-738 60 00 Electrolux Home Comfort Appliances • Torsvik Plant • Box 502 • S-562 28 Norrahammar • Sweden • Tel +46-36-31 80 00...