INSTALLATION

Connecting the reject water hose

The reject water hose (for discharge of water to a house-
hold waste pipe) can be extended up to 4 metres. The smallest
internal diameter is 13 mm. The bracket (supplied) should
be secured at a height of at least 50 mm and a maximum
of 500 mm above the top of the appliance.
Any of the following alternatives can be used for installing
the reject water hose:
• Connection to a waste pipe with a trap can be made if the
trap has an entry point of the type used for a dishwasher
discharge. If there is only one entry point and this is already
in use, the connector unit will need to be changed, and one
with two entry points used instead. The reject connector
from the water purifier should be after the drain, to prevent
water from splashing up into the sink when the water
purifier is in flushing mode. The reject water hose needs to
be routed in a curve up via the underside of the worktop or
sink bench. Fix the hose securely in place as shown in Fig.
A, using one of the hose clips and the bracket supplied.
Fit the connection piece supplied onto the straight end of
the appliance reject water hose by turning it anticlockwise.
• To discharge water from the reject water
hose straight into a sink, make sure the
bracket is fixed permanently to a surface
near the top edge of the sink, as illustrated.
• If the reject water is to be discharged into a
wall standpipe, observe the dimensions
shown here.

Connecting the feed water hose

Make sure that the black washers are in place when
securing the connectors at both ends of this hose. The
straight end of the hose is intended for connection to the
domestic plumbing. Check that the washer is in place,
then screw this end of the hose onto the shut-off valve on
the pipe supplying water to the appliance (see Fig. B).