IF THE RO 400 STOPS WORKING

To adjust the tap

1 Disconnect the electrical plug.
2 Pull the main tap pipe straight upwards as illustrated (Fig. A.)
3 Press and slide the tap lever across the top of the hole
for the main tap pipe (Fig. B).
4 Adjust the screw (Fig. C).
C1 If the flow from the tap is uneven or jerky
Turn the adjusting screw one half turn clockwise.
C2 If the appliance starts working on its own
Turn the adjusting screw one half turn anticlockwise.
5 Refit first the lever, then the main tap pipe. Check that
the seals/washers on the main tap pipe are in good
condition.
6 Reconnect the electrical plug and let the RO 400 flush
automatically.
7 Test the appliance. If the problem persists, adjust the
screw further.
24