Connecting Up The Appliance - Electrolux RO 400 User Manual

Direct flow
Hide thumbs Also See for RO 400:
Table of Contents

Advertisement

Connecting up the appliance

Before moving the RO 400 into its permanent place,
connect the three hoses to the appliance as shown in Fig. C.
Connect the purified water hose from the purified water
tap to the appliance. Press this end of the hose all the
way home, as far as the line marked on it (about 17
mm). Use the elbow (supplied) if space is restricted
behind the appliance.
Connect the end of the reject water hose (the one with
the bend) to the appliance, and secure it with one of the
hose clips supplied. Next screw the correct end of the
feed water hose onto the appliance. You can now turn
on the water supply by opening the valve, to check that
this coupling is fully watertight. Connect the wiring for
the indicator lights on the tap, then move the appliance
carefully into its permanent location.
Connect the electrical plug to the wall socket (Fig. D).
The appliance will now start working (flushing). The
appliance carries out this flushing operation every time it
is reconnected to the power supply.
No water from the appliance should be consumed
until you have followed the full "Flushing
procedure", as described on the next page.
After installing and testing the appliance, turn on the
appliance's drinking water tap and check that all the
connections are watertight. If any coupling is leaking,
disconnect the electrical plug, then tighten the hose clip
or nut more. Connect the appliance to the power supply
again. When the appliance has been installed for one
week, tighten the connections for the reject water and
feed water hoses again.
A leakage as small as just a few drops of water is
enough to start the water purifier working (when
it is not needed).
Leakages outside the actual appliance cannot be
detected by its leakage protection system.
Unless specifically stated otherwise in these
instructions, the valve on the feed water supply
pipe should be left in the open position for the
protection system of the RO 400 to function.
INSTALLATION
C
D
11