TECHNICAL CHARACTERISTICS

TYPE C CHIMNEY CONNECTION

• C13 :
concentric horizontal connection
• C33(x): concentric vertical connection
• C53(x): parallel chimney connection
• C63(x): concentric vertical connection without terminal
(Only in Germany and Luxemburg)
The maximum pressure drop in flue pipe (air inlet + flue gas outlet) cannot
exceed 100 Pa - see table below indicating the pressure drop for each
of the components).
A = fresh air supply
B = flue gas
1m straight pipe
90° elbow
45° elbow
Condensate recovery container
Terminal
This table is based on ACV equipment and cannot be applied as a rule
120
C
33(x)
I
O
C
53(x)
I
O
664Y5400•B
HeatMaster®
30N / 60N / 70N
100 N
A
B
A
B
Ø 80
Ø 150
Ø 100
Ø 150
6
1
6
2
15
2
15
5
6
1
6
2
_
2
_
4
20
10
20
20
C
33(x)
I
O
EN • 12
In the case of a concentric connection, the total flue pipe
length is limited to 6 meters.
A condensation outlet connected to the sewer must be
fitted close to the boiler to prevent the condensation
products from the chimney from running into the boiler.
To avoid condensation water running out of the terminal,
all horizontal flue ducts must be installed with a slight
downward slope toward the boiler.