Category
Ratio
Maximum fluid working pressure
Maximum air input pressure
Pump cycles per 1 gallon (3.8 liters)
Fluid flow at 60 cycles per minute
Fluid inlet size
Fluid outlet size
Air inlet size
Weight
Maximum pump operating temperature
* Sound level at 100 psi, 15 cycles per minute
* Sound power level at 100 psi, 15 cycles per minute
Wetted parts
* Tested in accordance with ISO 3744.
KEY:
Fluid Outlet Pressure - Black Curves
Air Consumption - Gray Curves
cycles per min
psi
bar
liters/min
To find Fluid Outlet Pressure (bar/psi) at a specific fluid flow (lpm/
gpm) and operating air pressure (bar/psi):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected fluid outlet
pressure curve (black). Follow left to scale and read fluid outlet
pressure.

Technical Data

16
240
16.8
200
14.0
A
160
11.2
120
B
8.4
80
5.6
C
40
2.8
0
0.0
1.5
gpm
5.7
FLUID FLOW (TEST FLUID: NO 10 MOTOR OIL)
Data
2:1
200 psi (14 bar)
100 psi (7 bar)
11
5.5 gpm (21 liters/min)
1–1/2 npt(f)
1 in. npt(f)
3/8 npsm(f)
40 lb (18.14 kg)
180_F (82_C)
62.6 dBa
71.8 dBa
Supply and Return Tubes: Nickel-plated carbon steel
Air Motor Base: Aluminum
Displacement Pump: Refer to manual 307983
A
100 psi (7 bar) air pressure
B
70 psi (4.9 bar) air pressure
C
40 psi (2.8 bar) air pressure
32
48
A
B
C
3.0
4.5
11.4
17
To find Pump Air Consumption (m#/min or scfm) at a specific fluid
flow (lpm/gpm) and operating air pressure (bar/psi):
1. Locate desired flow along bottom of chart.
2. Follow vertical line up to intersection with selected air consump-
tion curve (gray). Follow right to scale and read air consumption.
64
12.0
scfm
0.336
m#/min
10.0
0.280
8.0
0.224
6.0
0.168
4.0
0.112
2.0
0.056
6.0
23
307985