Troubleshooting - MICRO-EPSILON ELTROTEC Endolight FOT LED Instruction Manual

Led light source
Table of Contents

Advertisement

Instructions for Operation
8.2
Error
No light
No fan sound
No light, status LED is flashing
slowly.
No light, no fan sound, status LED
is flashing slowly.
No light, status LED is flashing
rapidly.
Light flickers.
No COM-Port connection pos-
sible.
ELTROTEC Endolight FOT LED

Troubleshooting

Possible cause
No or insufficient power supply
Operating mode is set to
Off.
Intensity setting is too low.
System temperature is low.
Overtemperature, air inlet and/or
outlet is covered.
Overtemperature due to broken
fan.
LED seems to be defective.
Low power supply.
No connection to COM-Port.
Wrong COM-Port, incorrect set-
tings.
Solution
Check cables and connector
plugs, replace power supply
unit if necessary.
Set operating mode to
MP.
Adjust the intensity (trigger
signal could be needed
depending on the settings).
Increase intensity.
No action required.
Please check if air inlets and
outlets are uncovered.
Minimum distance is 10 cm.
Please contact our technical
service, see Chap.
10.
Please contact our technical
service, see Chap.
10.
Power supply unit must be
24 VDC
10 %/ 55 W.
±
Please check cable and con-
nections.
Reset the settings, see Chap.
6.
or
On
Page 23