Indications for Use

Ventilation

The ZOLL Z Vent ventilator is indicated for use in the management of infant through adult
patients weighing greater than or equal to 5 kg with acute or chronic respiratory failure or
during resuscitation by providing continuous positive-pressure ventilation. The ZOLL Z Vent
ventilator is appropriate for use in hospitals, outside the hospital, during transport and in severe
environments where they may be exposed to rain, dust, rough handling, and extremes in
temperature and humidity. With an appropriate third-party filter in place, they may be operated
in environments where chemical and/or biological toxins are present. When marked with an
"MRI conditional" label, the ZOLL Z Vent ventilator is suitable for use in an MRI environment
with appropriate precautions. The ZOLL Z Vent ventilator is intended for use by skilled care
providers with knowledge of mechanical ventilation, emergency medical services (EMS)
personnel with a basic knowledge of mechanical ventilation, and by first responders under the
direction of skilled medical care providers.
Pulse Oximetry (SpO
The ZOLL Z Vent ventilator pulse oximeter with Masimo SET technology is intended for use
for continuous noninvasive monitoring of the oxygen saturation of arterial hemoglobin (SpO
and pulse rate. The pulse SpO
pediatric patients during both no motion and motion conditions, and for patients who are well
or poorly perfused, in hospitals, hospital-type facilities, or in mobile environments.

Features

Portable ventilator that you can use in the hospital, aeromedical and ground transport, mass
casualty situations, and extreme environments.
Multiple modes of ventilation for use with acute or chronic respiratory failure in both
intubated and non-intubated patients.
Intuitive user interface minimizes user training and protects existing settings from
inadvertent contact and manipulation.
Smart Help™ messages guide the user through on-screen commands when responding to
alarms.
Lightweight < 10 lbs. (4.4 kg) — for easy transport.
Rechargeable battery provides over 10 hours of operation (at factory default with pulse
oximeter operating).
Operating temperature range for extreme conditions: -26
Altitude compensation from - 685.8 m to 7620 m (- 2,250 to 25,000 ft).
Self-contained system able to operate with or without external oxygen.
Gas manifold design allows operation with both high and low-pressure oxygen sources. All
oxygen is delivered to the patient breathing circuit.
Sealed gas path with chemical/biological filter connected to assure safe breathing gas
supply.
Case and control panel protects components from weather and fluids.
9650-002360-01 Rev. A
)
2
oximeter and accessories are indicated for use with adult and
2
ZOLL Z Vent Ventilator Operator's Guide
General Information
C to 55
C (-15
F to 131
),
2
F).
1-9